  Acta Physica Sinica--1959, 15 (6)   Published: 15 June 1959
Select | Export to EndNote
CONTENT

REPORT ON THE MANUFACTURING OF SPECTROSCOPE FOR STEEL ANALYSIS

Acta Physica Sinica. 1959, 15 (6): 0277 doi: 10.7498/aps.15.277
Full Text: [PDF 385 KB] Download:(351)
Show Abstract
In accordance with the development of our national steel industry, we try to construct a spectroscope for the visual analysis of the compositions of steel or the other alloys. The work is completed in a course of 2 1/2 month. The whole apparatus consists of an auto-collimating spectroscope, a special desgined holder for specimens, and a high frequency activated alternating current are source. The model is somewhat like that produced by the firm of Fuess, but the whole optical systems are designed and computed according to the theory of optical abbora-tions. The auto-collimating objective is made achromatic, and the eyepiece is of Kolner type with magnification of 25X. With one and half prisms, each with 3 cm base, the spectroscope disperses the spectrum from 3900? to 7000?. The li-near dispersions of the final image of the system, at λ = 4358? and λ= 5893? are 0.89?/mm and 2.91?/mm, respectively. The resolving power △λ of the spectroscope at those wave lengths is 0.14? and 0.59?, respectively. The cireuit dia-gram of the arc source is also given.

ПРИМЕНЕНИЕ МЕТОДА СПЕКТРАЛЬНОГО АНАЛИЗА ДЛЯ ПОРОШКООБРАЗНЫХ ОБРАЗЦОВ К ЭЛЕКТРОВАКУУМНЫМ МАТЕРИАЛАМ

null
Acta Physica Sinica. 1959, 15 (6): 0282 doi: 10.7498/aps.15.282
Full Text: [PDF 186 KB] Download:(352)
Show Abstract
null

IMPROVEMENT OF ACCURACY IN THE SPECTRO-CHEMICAL ANALYSIS OF HIGH ALLOY STEELS

RESEARCH INSTITUTE OP IRON &. STEEL
Acta Physica Sinica. 1959, 15 (6): 0285 doi: 10.7498/aps.15.285
Full Text: [PDF 842 KB] Download:(474)
Show Abstract
wideThe application of spectro-chemical analysis to high alloy steel in our steel works has been limited by the accuracy of their methods. Through the investigation upon two typical high alloy steels, ‘P18' high speed steel and ‘Я1' stainless steel, it is proved that the minimum standard deviation that can Le reached by the photographic method of epectro-chemical analysis of such high alloy steels after adopting many improvements in each step of the analysis is about 1%. Many valuable experiences from our steel factories are introduced in this paper, and the problems concerning accuracy of the spectro-chemical analysis of high alloy steels are discussed.

BY THE SPECTRUM LINE WIDTH METHODS TO ANALYZE LAYER AFTER LAYER THE ALUMINIZED STEEL

Acta Physica Sinica. 1959, 15 (6): 0305 doi: 10.7498/aps.15.305
Full Text: [PDF 323 KB] Download:(371)
Show Abstract
null

КОЛИЧЕСТВЕННОЕ СПЕКТРАЛЬНОЕ ОПРЕДЕЛЕНИЕ ПРИМЕСЕЙ В МЕТАЛЕ ЦИРКОНИЯ

null
Acta Physica Sinica. 1959, 15 (6): 0311 doi: 10.7498/aps.15.311
Full Text: [PDF 283 KB] Download:(490)
Show Abstract
null

AUTOMATIC DEVICE FOR TYPE ИСП-22 SPECTROGRAPH

null
Acta Physica Sinica. 1959, 15 (6): 0316 doi: 10.7498/aps.15.316
Full Text: [PDF 99 KB] Download:(323)
Show Abstract
In this article, it briefly introduces that by means of the three electro time-relays to control the arc-burn period, the pre-burn period and the moving distance of the photographic box, it simplifies the procedure of the work, shortens the required time and greatly raises the efficiency of the work concerned.

PHOTO-ELECTRIC DIRECT-READING ATTACHMENT TO A MEDIUM QUARTZ SPECTROGRAPH AND ANALYSIS OF COPPER IN Al-ALLOY

null
Acta Physica Sinica. 1959, 15 (6): 0318 doi: 10.7498/aps.15.318
Full Text: [PDF 405 KB] Download:(477)
Show Abstract
Two movable photo-multiplier tubes are set in the position of the plate holder of a medium quartz spectrograph. The photo-current of each is amplified by an AC amplifier, and, after rectification, is used to charge a condenser. A thyratron is connected parallel to the condenser for the internal standard line (Al 2660?). At a present value of the voltage of this condenser, the thyratron operates so as to switch off the reading instrument which is connected with the other condenser for the analysis line (Cu 2247?). The final reading on the meter is proved to be proportional to the ratio of intensities of the two spectral lines.With the help of a set of standard samples, calibration curve for analysis of copper in Al-alloy is obtained. It is a straight lino in the concentration interval 2.3-6.7%. Beproducibility of the whole instrument including the light source is measured by repeating ten times the calibration process, each time determining the content of Cu in a given sample. The mean relative error of those ten determinations is 4%. The results of spectroscopic determination and chemical analysis have a deviation of 1%.

THE DETERMINATION OF IMPURITIES CONTAINED IN PURE ANTIMONY BY QUANTITATIVE SPECTRAL ANALYSIS

null
Acta Physica Sinica. 1959, 15 (6): 0325 doi: 10.7498/aps.15.325
Full Text: [PDF 486 KB] Download:(445)
Show Abstract
A quantitative spectral method is usod to determino the various impurities contained in the 99.99% pure antimony. The antimony metal is ground to powder form as sample. A cortain amount of chemical salt, one of its component is the impurity element to be determined, in the form of powder is added to the sample, to secure a series of standards by several times of dilution. All the samples and standards are placed in the respective craters drilled on carbon rods. Each sample is photographed for five times by a Zeiss Qu-24 medium size quartz spec-trograph in same spectral plate. The result is obtained by linear interpolation method. The interrupted arc with longest interrupted time and exposure time is found to be a suitable source.Several impurities, including Ca, Si, Mg, Cu Fe, Al and Pb are analysed successfully at sensitivities from 10-5 to 10-6. The experimental error is only estimated about 30-

КОЛИЧЕСТВЕННЫИ АНАЛИЗ СПЕКТРОВ ПЛАТИНЫ В КАТАЛИЗАТОРЕ АЛЮМИНИТА НЕФТИ

null
Acta Physica Sinica. 1959, 15 (6): 0331 doi: 10.7498/aps.15.331
Full Text: [PDF 358 KB] Download:(460)
Show Abstract
null

THE GROUP ANALYSIS OF HYDROCARBON COMPOUNDS BY THE INTEGRAL INTENSITIES OF INFRARED SPECTRA

HSU SHIH-CHIOU
Acta Physica Sinica. 1959, 15 (6): 0337 doi: 10.7498/aps.15.337
Full Text: [PDF 183 KB] Download:(412)
Show Abstract
Group analysis of hydrocarbon compounds by integral intensities of infrared spectra was obtained. The results of determination of the number of atomic groups CH2 and CH3 were quite good. It seems justifiable that this method could be used to analyse other types of structural groups.