Influence of charge cloud size on performance of UV photon-counting imaging detector

Liu Yong-An Yan Qiu-Rong Sheng Li-Zhi Zhao Bao-Sheng Zhao Fei-Fei Hu Hui-Jun

Influence of charge cloud size on performance of UV photon-counting imaging detector

Liu Yong-An, Yan Qiu-Rong, Sheng Li-Zhi, Zhao Bao-Sheng, Zhao Fei-Fei, Hu Hui-Jun
PDF
Get Citation
  • The size of charge cloud is examined as a function of acceleration voltage, distance between MCP and anode, and MCP gain. The performance of photon counting imaging detector is significantly affected by charge cloud size. In this paper, the influence of charge cloud size on the performance of UV photon-counting imaging systems is investigated. Modulation distortion, "S" distortion and their cause are discussed. Then, Monte Carlo simulations for anode decode with different charge cloud sizes are carried out. And finally, the effects of acceleration voltage, distance between MCP and WSA, and MCP gain on the system performance are tested and some practical solutions of modulation and "S" distortion are suggested.
    • Funds:
    [1]

    Jagutzki O, Barnstedt J, Spillmann U, Spielberger L,Mergel V,Ullmann-Pfleger K, Grewing M, Schmidt-Bocking H 2000 Proc. SPIE 3764 61

    [2]

    Lapington J S, Chakrabarti S, Cook T, Gsell J C, Gsell V T 2003 Nucl. Instr. and Meth. A 513 159

    [3]

    Barnstedt J, Grewing M 2002 Nucl. Instr. and Meth. A 477 268

    [4]

    Lapington J S 2003 Proc. SPIE 4854 191

    [5]

    Liu Y A, Zhao B S, Zhu X P, Miao Z H, Zhang X H, Zou W 2009 Acta Phot. Sin. 38 750 (in Chinese)[刘永安、赵宝升、朱香平、缪震华、张兴华、邹 玮 2009 光子学报 38 750]

    [6]

    Zhang X H, Zhao B S, Miao Z H, Zhu X P, Liu Y A, Z W 2008 Acta Phys. Sin. 57 4238 (in Chinese)[张兴华、赵宝升、缪震华、朱香平、刘永安、邹 玮 2008 物理学报 57 4238]

    [7]

    Miao Z H, Zhao B S, Liu Y A, Zhu X P, Zhang X H 2007 Acta Phot. Sin. 36 2215 (in Chinese)[缪震华、赵宝升、刘永安、朱香平、张兴华 2007光子学报 36 2215]

    [8]

    Smith A, Kessel R, Lapington J S, Walton D M 1989 Rev. Sci. Instrum. 60 3509

    [9]

    Saito M, Saito Y, Asamura K, Mukai T 2007 Rev. Sci. Instrum. 78 023302

    [10]

    Price G J, Fraser G W 2001 Nucl. Instr. and Meth. A 474 188

    [11]

    Tremsin A S, Siegmund O H W 1999 Rev. Sci. Instrum. 70 3282

    [12]

    Grantham S E, Miesak E J, Reese P C T, Richardson M C 1994 Proc. SPIE 2273 108

    [13]

    Zhang X H, Zhao B S, Liu Y A, Miao Z H, Zhu X P, Zhao F F 2009 Acta Phys. Sin. 58 1779 (in Chinese)[张兴华、赵宝升、刘永安、缪震华、朱香平、赵菲菲 2009 物理学报 58 1779]

  • [1]

    Jagutzki O, Barnstedt J, Spillmann U, Spielberger L,Mergel V,Ullmann-Pfleger K, Grewing M, Schmidt-Bocking H 2000 Proc. SPIE 3764 61

    [2]

    Lapington J S, Chakrabarti S, Cook T, Gsell J C, Gsell V T 2003 Nucl. Instr. and Meth. A 513 159

    [3]

    Barnstedt J, Grewing M 2002 Nucl. Instr. and Meth. A 477 268

    [4]

    Lapington J S 2003 Proc. SPIE 4854 191

    [5]

    Liu Y A, Zhao B S, Zhu X P, Miao Z H, Zhang X H, Zou W 2009 Acta Phot. Sin. 38 750 (in Chinese)[刘永安、赵宝升、朱香平、缪震华、张兴华、邹 玮 2009 光子学报 38 750]

    [6]

    Zhang X H, Zhao B S, Miao Z H, Zhu X P, Liu Y A, Z W 2008 Acta Phys. Sin. 57 4238 (in Chinese)[张兴华、赵宝升、缪震华、朱香平、刘永安、邹 玮 2008 物理学报 57 4238]

    [7]

    Miao Z H, Zhao B S, Liu Y A, Zhu X P, Zhang X H 2007 Acta Phot. Sin. 36 2215 (in Chinese)[缪震华、赵宝升、刘永安、朱香平、张兴华 2007光子学报 36 2215]

    [8]

    Smith A, Kessel R, Lapington J S, Walton D M 1989 Rev. Sci. Instrum. 60 3509

    [9]

    Saito M, Saito Y, Asamura K, Mukai T 2007 Rev. Sci. Instrum. 78 023302

    [10]

    Price G J, Fraser G W 2001 Nucl. Instr. and Meth. A 474 188

    [11]

    Tremsin A S, Siegmund O H W 1999 Rev. Sci. Instrum. 70 3282

    [12]

    Grantham S E, Miesak E J, Reese P C T, Richardson M C 1994 Proc. SPIE 2273 108

    [13]

    Zhang X H, Zhao B S, Liu Y A, Miao Z H, Zhu X P, Zhao F F 2009 Acta Phys. Sin. 58 1779 (in Chinese)[张兴华、赵宝升、刘永安、缪震华、朱香平、赵菲菲 2009 物理学报 58 1779]

  • [1] Internal dynamic detection of soliton molecules in a Ti: sapphire femtosecond laser. Acta Physica Sinica, 2020, (): . doi: 10.7498/aps.69.20191989
    [2] Chen Ya-Bo, Yang Xiao-Kuo, Wei Bo, Wu Tong, Liu Jia-Hao, Zhang Ming-Liang, Cui Huan-Qing, Dong Dan-Na, Cai Li. Ferromagnetic resonance frequency and spin wave mode of asymmetric strip nanomagnet. Acta Physica Sinica, 2020, 69(5): 057501. doi: 10.7498/aps.69.20191622
    [3] The spring oscillator model degenerated into the coupled-mode theory by using secular perturbation theory. Acta Physica Sinica, 2020, (): . doi: 10.7498/aps.69.20191505
    [4] Thermodynamics of Laser Plasma Removal of Micro and Nano Particles. Acta Physica Sinica, 2020, (): . doi: 10.7498/aps.69.20191933
    [5] High-speed and large-scale light-sheet microscopy with electrically tunable lens. Acta Physica Sinica, 2020, (): . doi: 10.7498/aps.69.20191908
    [6] Research on few-mode PAM regenerator based on nonlinear optical fiber loop mirror. Acta Physica Sinica, 2020, (): . doi: 10.7498/aps.69.20191858
    [7] Li Chuang, Li Wei-Wei, Cai Li, Xie Dan, Liu Bao-Jun, Xiang Lan, Yang Xiao-Kuo, Dong Dan-Na, Liu Jia-Hao, Chen Ya-Bo. Flexible nitrogen dioxide gas sensor based on reduced graphene oxide sensing material using silver nanowire electrode. Acta Physica Sinica, 2020, 69(5): 058101. doi: 10.7498/aps.69.20191390
    [8] Zhang Ji-Ye, Zhang Jian-Wei, Zeng Yu-Gang, Zhang Jun, Ning Yong-Qiang, Zhang Xing, Qin Li, Liu Yun, Wang Li-Jun. Design of gain region of high-power vertical external cavity surface emitting semiconductor laser and its fabrication. Acta Physica Sinica, 2020, 69(5): 054204. doi: 10.7498/aps.69.20191787
    [9] Zhang Zhan-Gang, Lei Zhi-Feng, Tong Teng, Li Xiao-Hui, Wang Song-Lin, Liang Tian-Jiao, Xi Kai, Peng Chao, He Yu-Juan, Huang Yun, En Yun-Fei. Comparison of neutron induced single event upsets in 14 nm FinFET and 65 nm planar static random access memory devices. Acta Physica Sinica, 2020, 69(5): 056101. doi: 10.7498/aps.69.20191209
  • Citation:
Metrics
  • Abstract views:  3324
  • PDF Downloads:  737
  • Cited By: 0
Publishing process
  • Received Date:  22 December 2009
  • Accepted Date:  02 June 2010
  • Published Online:  15 April 2011

Influence of charge cloud size on performance of UV photon-counting imaging detector

  • 1. (1)State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119,China; (2)State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119,China;Graduate University of Chinese Academy of Sciences, Beijing 100049,China

Abstract: The size of charge cloud is examined as a function of acceleration voltage, distance between MCP and anode, and MCP gain. The performance of photon counting imaging detector is significantly affected by charge cloud size. In this paper, the influence of charge cloud size on the performance of UV photon-counting imaging systems is investigated. Modulation distortion, "S" distortion and their cause are discussed. Then, Monte Carlo simulations for anode decode with different charge cloud sizes are carried out. And finally, the effects of acceleration voltage, distance between MCP and WSA, and MCP gain on the system performance are tested and some practical solutions of modulation and "S" distortion are suggested.