NO-STANDARDS QUANTITATIVE EDS ANALYSIS OF MULTICOMPONENT ALLOYS

Zhang Ren-ji Wu Zi-qin

NO-STANDARDS QUANTITATIVE EDS ANALYSIS OF MULTICOMPONENT ALLOYS

Zhang Ren-ji, Wu Zi-qin
PDF
Get Citation

(PLEASE TRANSLATE TO ENGLISH

BY GOOGLE TRANSLATE IF NEEDED.)

Metrics
  • Abstract views:  2798
  • PDF Downloads:  474
  • Cited By: 0
Publishing process
  • Received Date:  10 October 1981
  • Published Online:  05 May 1982

NO-STANDARDS QUANTITATIVE EDS ANALYSIS OF MULTICOMPONENT ALLOYS

  • 1. 北京大学物理系

Abstract: A direct no-standards quantitative analysis method of binary alloy is developed and applied to multicomponent alloys including 7-components and 8-components steel samples in which the contents of some components are about 0.25-1.0%. As compared with the indirect no-standards method (Buss et al.), the accuracy of the present method is generally better and the analytical time shorter. It only needs about 10 seconds in calculating the constituents of a 8-components alloy from their characteristic X-ray intensities using a computer with a speed about 130,000 cps. The analytical results of binary alloys, especially NaCl, using this modified method are better than before.