Based on the original design of T.G.Leighton's conical bubble U_tube,an improve d apparatus is set up. The light pulses and spectra of air bubbles in water are detected. Results show that the width of a light pulse ranges from a few of hun dred picoseconds to a few nanoseconds. The vibrational spectra of water molecule s in the near_infrared have been obtained,and its intensity increases toward th e infrared. The spectra of conical bubble in NaCl solution is also detected.
-
Keywords:
- sonoluminescence /
- conical bubble /
- light pulse /
- spectra
Catalog
Metrics
- Abstract views: 7177
- PDF Downloads: 770