Study of coded source neutron imaging based on a compact accelerator

Wang Sheng Zou Yu-Bin Wen Wei-Wei Li Hang Liu Shu-Quan Wang Hu Lu Yuan-Rong Tang Guo-You Guo Zhi-Yu

Citation:

Study of coded source neutron imaging based on a compact accelerator

Wang Sheng, Zou Yu-Bin, Wen Wei-Wei, Li Hang, Liu Shu-Quan, Wang Hu, Lu Yuan-Rong, Tang Guo-You, Guo Zhi-Yu
PDF
Get Citation

(PLEASE TRANSLATE TO ENGLISH

BY GOOGLE TRANSLATE IF NEEDED.)

  • Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attention in recent years, in spite of its relatively low neutron fluence. In order to keep a definite neutron flux above a reasonable level on a compact accelerator based neutron imaging system, one could not set the collimation ratio to be as high as the reactor neutron source to obtain a high resolution. Coded source could increase the collimation ratio without reducing the neutron flux much. It may benefit neutron imaging system in the case of low yield neutron source. Since 2005, several laboratories in Germany and USA have carried out simulation and experiments of coded source neutron imaging. Those experiments are based on the reactor neutron sources, which have high neutron yield and low scattered neutron background. Recently, a preliminary coded source neutron imaging experiment was carried out on PKUNIFTY (Peking University Neutron Imaging Facility), which is based on a 2 MeV deuteron RFQ accelerator. It is the first time that coded source neutron imaging has been applied to an accelerator-based neutron source. Projections of coded neutron source are taken with a neutron yield of 2.6×1011 s-1. With Wiener filter deconvolution and Lucy-Richardson maximum likelihood iteration algorithm, the experimental projections are reconstructed successfully. Because the accumulated neutron fluence is low and the neutron background is high, the signal-to-noise ratio of reconstructed images is not good enough, which will be improved by reducing the neutron background.
    • Funds: Project supported by the National Basic Research Program of China (Grant No. 2010CB833106) and the Instrument and Equipment Projects of Peking University, China.
    [1]

    Zhang X S 2010 M. S. Dissertation (Beijing: Peking University) (in Chinese) [张雪霜 2010 硕士学位论文 (北京: 北京大学)]

    [2]

    Grunauer F 2005 Ph. D. Dissertation (Germany: Technische Universitaet Muenchen)

    [3]

    Damato A L, Binns P, Lanza R C 2007 IEEE Nuclear Science Symposium Conference Record 2007 Hawaii, USA, October 28-November 3, 2007 p1725

    [4]

    Xiao Z Y, Mishra K K, Hawari A I, Ayman I, Bilheux, Hassina Z, Bingham, Philip R, Tobin J, Kenneth W 2009 IEEE Nuclear Science Symposium Conference Record 2009 Orlando, USA, October 24-November 1, 2009 p1289

    [5]

    Li Y J, Huang Z F, Chen Z Q, Kang K J, Xiao Y S, Wang X W, Wei J, Long C K 2011 Nucl. Instr. Meth. A 651 131

    [6]

    Wang S, Zou Y B, Zhang X S, Lu Y R, Guo Z Y 2011 Nucl. Instr. Meth. A 651 187

    [7]

    Zou Y B, Schillinger B, Wang S, Zhang X S, Guo Z Y, Lu Y R 2011 Nucl. Instr. Meth. A 651 192

    [8]

    Zou Y B, Wen W W, Guo Z Y, Lu Y R, Peng S X, Zhu K, Yan X Q, Gao S L, Zhao J, Li H, Zhou Q F, Ren H T, Zhang M, L P N, Guo J M, Tang G Y, Mo D W, Chen J E 2011 Nucl. Instr. Meth. A 651 62

  • [1]

    Zhang X S 2010 M. S. Dissertation (Beijing: Peking University) (in Chinese) [张雪霜 2010 硕士学位论文 (北京: 北京大学)]

    [2]

    Grunauer F 2005 Ph. D. Dissertation (Germany: Technische Universitaet Muenchen)

    [3]

    Damato A L, Binns P, Lanza R C 2007 IEEE Nuclear Science Symposium Conference Record 2007 Hawaii, USA, October 28-November 3, 2007 p1725

    [4]

    Xiao Z Y, Mishra K K, Hawari A I, Ayman I, Bilheux, Hassina Z, Bingham, Philip R, Tobin J, Kenneth W 2009 IEEE Nuclear Science Symposium Conference Record 2009 Orlando, USA, October 24-November 1, 2009 p1289

    [5]

    Li Y J, Huang Z F, Chen Z Q, Kang K J, Xiao Y S, Wang X W, Wei J, Long C K 2011 Nucl. Instr. Meth. A 651 131

    [6]

    Wang S, Zou Y B, Zhang X S, Lu Y R, Guo Z Y 2011 Nucl. Instr. Meth. A 651 187

    [7]

    Zou Y B, Schillinger B, Wang S, Zhang X S, Guo Z Y, Lu Y R 2011 Nucl. Instr. Meth. A 651 192

    [8]

    Zou Y B, Wen W W, Guo Z Y, Lu Y R, Peng S X, Zhu K, Yan X Q, Gao S L, Zhao J, Li H, Zhou Q F, Ren H T, Zhang M, L P N, Guo J M, Tang G Y, Mo D W, Chen J E 2011 Nucl. Instr. Meth. A 651 62

Metrics
  • Abstract views:  6181
  • PDF Downloads:  1049
  • Cited By: 0
Publishing process
  • Received Date:  26 November 2012
  • Accepted Date:  09 January 2013
  • Published Online:  05 June 2013

/

返回文章
返回