A single-element interferometer for measuring parallelism and uniformity of transparent plate

Lan Bin Feng Guo-Ying Zhang Tao Liang Jing-Chuan Zhou Shou-Huan

Citation:

A single-element interferometer for measuring parallelism and uniformity of transparent plate

Lan Bin, Feng Guo-Ying, Zhang Tao, Liang Jing-Chuan, Zhou Shou-Huan
PDF
Get Citation

(PLEASE TRANSLATE TO ENGLISH

BY GOOGLE TRANSLATE IF NEEDED.)

  • The transparent plates (such as organic glass, plastic plate) are widely used in the construction industry, high-tech products and scientific research applications, and its parallelism and uniformity measurement in the manufacture and quality control become more and more inevitable. Interferometer is a label-free, high-precision, and high-efficient device that can be used in many fields. According to a single-element interferometer, we demonstrate a measurement for the parallelism and uniformity of transparent medium. Beam-splitter cube is a key component. Half of plane wave laser source passes through the measured medium and the remaining half directly passes through the air, then these two halves with different optical paths meet in the beam-splitter cube. The parallelism or uniformity is determined by calculating interference fringe shift number during rotating the measured sample. The coherent beam is divided into two parts by a beam-splitter, one passes through the lens and then arrives at a photoelectric counter, and the other arrives at the observation plane of the charge-coupled device. The photoelectric counter is used to count the integer part of fringe shift number during rotating the sample; and the decimal part can be detected by calculating the phase difference of the two interferograms captured before and after rotation. The measurement principle of the proposed device is analyzed in detail, and the numerical simulations of the fringe shift number and the gray level changing with the sample rotation angle, the thickness and the refractive index of the sample are carried out. The simulation results show that the bigger the rotation angle, thickness and refractive index of the sample, the greater the fringe shift number will be. Therefore, the measurement accuracy can be improved by increasing the rotation angle and the thickness of the sample. In addition, we also simulate the measurement processes of two kinds of samples, which are unparallel and inhomogeneous transparent plates. The simulation results prove the feasibility and high accuracy of the proposed method. Finally, the optical experiment is conducted to demonstrate the practicability of the present device. The parallelism of a cuvette used for more than one year, is tested by our device. The results show that the difference in thickness between the cuvettes is on a micron scale, the peak-valley (PV) value is 9.92 m, and the root mean square (RMS) value is 2.2 m. And the difference between the contrast test results and the results from the proposed method is very small, the PV value is 0.569 m, and the RMS value is 0.131 m. The stability and repeatability of the proposed setup are tested in the experimental condition. The mean value and standard deviation of the fringe shift number during 30 min are 0.0012 and 0.0008, respectively. These results further testify the high accuracy and stability of our method. In conclusion, the performance of our measurement method is demonstrated with numerical simulation and optical experiment.
      Corresponding author: Feng Guo-Ying, guoing_feng@scu.edu.cn
    • Funds: Project supported by the National Natural Science Foundation of China (Grant No. 11574221).
    [1]

    Chen L F, Ren Y Q, Li J 2010 Opt. Eng. 49 050503

    [2]

    Jiang X Q, Wang K W, Gao F, Muhamedsalih H 2010 Appl. Opt. 49 2903

    [3]

    Wang D D, Yang Y Y, Chen C, Zhuo Y M 2011 Appl. Opt. 50 2342

    [4]

    Chen L F, Guo X F, Hao J J 2013 Appl. Opt. 52 3655

    [5]

    Zhang T, Feng G Y, Song Z Y, Zhou S H 2014 Opt. Commun. 332 14

    [6]

    Lan B, Feng G Y, Zhang T, Zhou S H 2017 J. Mod. Opt. 64 8

    [7]

    Wang Y, Qiu L R, Yang J M, Zhao W Q 2013 Optik 124 2825

    [8]

    Bai H Y, Shan M G, Zhong Z, Guo L L, Zhang Y B 2015 Opt. Lasers Eng. 75 1

    [9]

    Bai Y, Zhao W J, Ren D M, Qu Y C, Liu C, Yuan J H, Qian L M, Chen Z L 2012 Acta Phys. Sin. 61 094218 (in Chinese) [白岩, 赵卫疆, 任德明, 曲彦臣, 刘闯, 袁晋鹤, 钱黎明, 陈振雷 2012 物理学报 61 094218]

    [10]

    Du J, Zhao W J, Qu Y C, Chen Z L, Geng L J 2013 Acta Phys. Sin. 62 184206 (in Chinese) [杜军, 赵卫疆, 曲彦臣, 陈振雷, 耿利杰 2013 物理学报 62 184206]

    [11]

    Wang Y, Qiu L R, Song Y X, Zhao W Q 2012 Meas. Sci. Technol. 23 055204

    [12]

    Takeda M, Ina H, Kobayashi S 1982 J. Opt. Soc. Am. 72 156

    [13]

    Du Y Z, Feng G Y, Li H R, Vargas J, Zhou S H 2012 Opt. Express 20 16471

    [14]

    Lan B, Feng G Y, Dong Z L, Zhang T, Zhou S H 2016 Optik 127 5961

    [15]

    Ferrari J A, Frins E M 2007 Opt. Commun. 279 235

  • [1]

    Chen L F, Ren Y Q, Li J 2010 Opt. Eng. 49 050503

    [2]

    Jiang X Q, Wang K W, Gao F, Muhamedsalih H 2010 Appl. Opt. 49 2903

    [3]

    Wang D D, Yang Y Y, Chen C, Zhuo Y M 2011 Appl. Opt. 50 2342

    [4]

    Chen L F, Guo X F, Hao J J 2013 Appl. Opt. 52 3655

    [5]

    Zhang T, Feng G Y, Song Z Y, Zhou S H 2014 Opt. Commun. 332 14

    [6]

    Lan B, Feng G Y, Zhang T, Zhou S H 2017 J. Mod. Opt. 64 8

    [7]

    Wang Y, Qiu L R, Yang J M, Zhao W Q 2013 Optik 124 2825

    [8]

    Bai H Y, Shan M G, Zhong Z, Guo L L, Zhang Y B 2015 Opt. Lasers Eng. 75 1

    [9]

    Bai Y, Zhao W J, Ren D M, Qu Y C, Liu C, Yuan J H, Qian L M, Chen Z L 2012 Acta Phys. Sin. 61 094218 (in Chinese) [白岩, 赵卫疆, 任德明, 曲彦臣, 刘闯, 袁晋鹤, 钱黎明, 陈振雷 2012 物理学报 61 094218]

    [10]

    Du J, Zhao W J, Qu Y C, Chen Z L, Geng L J 2013 Acta Phys. Sin. 62 184206 (in Chinese) [杜军, 赵卫疆, 曲彦臣, 陈振雷, 耿利杰 2013 物理学报 62 184206]

    [11]

    Wang Y, Qiu L R, Song Y X, Zhao W Q 2012 Meas. Sci. Technol. 23 055204

    [12]

    Takeda M, Ina H, Kobayashi S 1982 J. Opt. Soc. Am. 72 156

    [13]

    Du Y Z, Feng G Y, Li H R, Vargas J, Zhou S H 2012 Opt. Express 20 16471

    [14]

    Lan B, Feng G Y, Dong Z L, Zhang T, Zhou S H 2016 Optik 127 5961

    [15]

    Ferrari J A, Frins E M 2007 Opt. Commun. 279 235

Metrics
  • Abstract views:  4866
  • PDF Downloads:  251
  • Cited By: 0
Publishing process
  • Received Date:  10 November 2016
  • Accepted Date:  29 November 2016
  • Published Online:  05 March 2017

/