用脉冲取样光检测方法减小Rb87频标的光频移

CSTR: 32037.14.aps.30.1

REDUCTION OF LIGHT SHIFT IN Rb87 FREQUENCY STANDARD USING PULSE SAMPLING OPTICAL DETECTION METHOD

CSTR: 32037.14.aps.30.1
PDF
导出引用
  • 本文提出了利用脉冲光抽运,脉冲取样光检测,连续微波共振的方案以减小被动式Rb87频标中的光频移。对Rb87基态超精细能级0—0跃迁的共振线形函数和光频移作了理论计算。实验结果定性地与理论符合,利用这种方案可望能改善被动式Rb87频标的长期频率稳定度。

     

    Device of pulse optical pumping and pulse sampling optical detection is presentedto reduce the light shift in Rb87 atomic frequency standard. The 0-0 transitionlineshape and light shift is calculated. It is qualitatively, inagreement with the experimen-tal results. With this device, one may expect to improve the long term frequency sta-bility of the passive Rb87 atomic frequeney standard.

     