85Rb灯对87Rb原子的光抽运

CSTR: 32037.14.aps.33.116

OPTICAL PUMPING OF 87Rb ATOMS USING 85Rb LAMP

CSTR: 32037.14.aps.33.116
PDF
导出引用
  • 本文对用85Rb灯不经滤光泡直接对87Rb吸收泡的光抽运作了观测,得到了比传统的用87Rb灯经85Rb滤光泡对87Rb吸收泡进行光抽运更强的基态0—0跃迁共振讯号。并在一定温度下观察到负的共振讯号。到目前为止,还不能对这种负的共振讯号作出解释。同时还测量了共振线宽和光频移。对在87Rb原子频标中应用的可能性作了评述。

     

    An optical pumping device, consisting of only 85Rb lamp and 87Rb absorption bulb, is used. The 0-0 transition resonance signal of 87Rb ground state is found to be greater than that in the conventional optical pumping device, in which the 87Rb lamp, 85Rb filter and 87Rb absorption bulb are used. In a definite temperature range, a negative resonance signal is observed. Up to now, it has not been explained yet. The line-width and optical frequency shift are measured. The possibility of applying this device in 87Rb atomic frequency standard is discussed.

     