导出引用
  • 研制了一台五通道ROSS-FILTER-PIN软X射线能谱仪,能谱范围为0.28—1.56keV.它由5个连续能段组成,每个能段的起止边由罗斯滤片对(ROSS-FILTERS)的L或K吸收边确定.罗斯滤片对的厚度通过优化计算得到,为了使每个通道的灵敏区外响应(即所测能段外响应)与通道总响应之比最小,在滤片对的第二滤片上镀上了一定厚度的第一滤片材料;为了缩减滤片表面积以增强低能滤片的抗冲击能力及方便滤片加工,能谱仪采用了小探测面积的PIN探测器(1mm2).借助此能谱仪,测量得到了喷气式Z箍缩(Z-pinch)等离子体辐射软X射线能谱的分布,并研究了软X射线产额随箍缩状况的变化趋势.

     

    A ROSS-FILTER-PIN spectrometer in the spectral range of 0.28keV —1.56keV was developed to study the soft X-ray radiation emitted from gas-puff Z-pinch plasma. It is composed of five channels covering the energy interval of interest without gaps. Soft X-ray spectral energy cuts were determined by the L absorption edges of selected filter elements (K absorption edges being used for light filter elements), and the optimum thickness of filter material was designed using computer code. To minimize the residual sensitivity outside the sensitivity range of each channel, element of the first filter was added into the second filter of all the Ross pair. To diminish the area of each filter, PIN detector with small sensitive area of 1 mm2 was adopted for the spectrometer. A filter with small area is easy to fabricate and would be helpful to withstand the Z-pinch discharge shock wave. With this ROSS-FILTER-PIN spectrometer, the energy spectra of soft X-ray from a small gas-puff Z-pinch were investigated, and the correlation between the soft X-ray yield and the plasma implosion state was also studied.

     