搜索

x
中国物理学会期刊

可激发气体振动弛豫时间的两频点声测量重建算法

CSTR: 32037.14.aps.65.134302

Algorithm for reconstructing vibrational relaxation times in excitable gases by two-frequency acoustic measurements

CSTR: 32037.14.aps.65.134302
PDF
导出引用
  • 振动弛豫时间是可激发气体分子内外自由度能量转移速率的宏观体现, 它决定了声吸收谱峰值点对应的弛豫频率. 本文给出了等温、绝热定压和绝热定容三种不同热力学过程下振动弛豫时间的相互关系; 基于Petculescu和Lueptow 2005 Phys. Rev. Lett. 94 238301 的弛豫过程合成算法, 推导了单一压强下两频点声测量值的弛豫时间重建算法. 该算法可应用于等温、绝热定压、绝热定容弛豫时间和弛豫频率的重建测量, 并避免了弛豫时间传统声测量方法需要不断改变气体腔体压强的问题. 仿真结果表明, 对于室温下CO2, CH4, Cl2, N2 和O2组成的多种气体, 重建的弛豫时间和弛豫频率与实验数据相符.

     

    Vibrational relaxation time is a parameter describing the macroscopic behavior of vibrational energy transition rate between molecular internal degrees of freedom (DOF) and external DOF in excitable gas, which determines the relaxation frequency of the maximum point in acoustic absorption spectrum. To measure the vibrational relaxation time, the traditional methods are used to obtain the acoustic absorption spectra by changing the ambient pressure at several operating frequencies. However, these traditional methods are not suitable for real-time measurement due to the complexity of equipment implementation and the non-ideality of test gas under high pressure. In order to solve those problems, we have developed an algorithm 2013 Meas. Sci. Technol. 24 055002 to capture the primary vibrational relaxation processes only based on the measurements of sound absorption and sound speed at two operating frequencies and a single pressure. But the algorithm only can reconstruct the absorption maximum and it cannot capture the relaxation time with high precision. To measure the frequency dependence of the complex effective specific heat of the relaxing gas, an algorithm synthesizing relaxation processes is given by Petculescu and Lueptow 2005 Phys. Rev. Lett. 94 238301. In its derivation process, relaxational angular frequency was set to be the inverse ratio to relaxation time. However, the relaxational angular frequency was measured in the adiabatic process of transmission thermodynamic, while the relaxation time was obtained in the thermodynamic isothermal process, the derivation confused the two thermodynamic processes, making the algorithm unable to capture the relaxation frequency with high precision. In order to estimate the relaxation time with higher accuracy, in this paper we first obtain the theoretical relationship among the relaxation times under the three types of thermodynamics conditions, i. e., isothermal, adiabatic constant pressure and adiabatic constant volume. Then we correct the relaxation time derivation and propose our corrected algorithm to reconstruct the relaxation frequencies and relaxation times under the conditions of isothermal, adiabatic constant pressure and adiabatic constant volume. In experiments and simulations, the relaxation times and relaxation frequencies reconstructed by our corrected algorithm for various gas compositions including carbon dioxide, methane, chlorine, nitrogen, and oxygen around room temperature are consistent with the experimental data.

     

    目录

    /

    返回文章
    返回