Sensitive detection of weak magnetic fields is an important application of quantum sensing, with implications for fundamental physics, inertial navigation, and biomagnetic measurements. Although spinbased sensors have achieved high sensitivities over a broad frequency range, extending their performance to sub-hertz frequencies remains challenging because slow fluctuations of experimental parameters and longterm drifts can dominate the measurement noise. Here, we theoretically investigate and experimentally demonstrate a quantum sensor based on a hybrid nuclear-spin system of
129Xe and
131Xe, combining controllable feedback-mediated coupling with systematic suppression of low-frequency technical noise. The two xenon isotopes are polarized through spin-exchange collisions with optically pumped
87Rb atoms, which also provide an optical readout of their transverse spin precession. Their precession frequencies are continuously tracked using phase-locked feedback, and a differential combination of the two frequency signals suppresses common magnetic-field fluctuations while retaining sensitivity to pseudomagnetic perturbations. We establish a dynamical model of the hybrid spin system and analyze how fluctuations of the optical and magnetic parameters enter the measured output. Guided by this analysis, we experimentally characterize the contributions from pump and probe laser power and frequency fluctuations, vapor-cell temperature variations, and bias-field fluctuations. Optimization of the operating phase reduces the coupling of pump-power fluctuations to the differential signal, while control of the remaining experimental parameters improves the stability required for low-frequency measurements. These measurements identify the dominant technical noise sources and provide a basis for evaluating the sensor performance.
To enhance the signal response, we introduce an external feedback coil that establishes a tunable effective interaction between the two nuclear-spin ensembles. This interaction modifies the coupled spin dynamics and produces a non-Hermitian exceptional point, near which the difference between the two mode frequencies exhibits an enhanced response to weak perturbations. Under the experimental operating conditions, the response slope to the target pseudomagnetic field is increased by approximately a factor of 3.5. We distinguish this enhancement of signal responsivity from an improvement in the fundamental quantum limit of parameter estimation. The present sensor operates in a regime limited by technical noise, and its practical sensitivity is determined jointly by the signal response and the measured output noise. The performance improvement therefore relies on combining response enhancement with noise suppression.
The resulting sensor achieves a pseudomagnetic-field sensitivity better than 43 fT/Hz
1/2 throughout the 0.001–0.1 Hz frequency range. These results demonstrate a route to sensitive low-frequency measurements using coupled noble-gas nuclear spins. The combination of differential spin readout, optimized operating conditions, and controllable feedback-mediated interactions provides a platform for further im-