  • 金刚石探测器具有响应快、灵敏度高、动态范围大、平响应、击穿电压高、抗辐射等优点, 广泛运用于X射线测量. 利用化学气相沉积方法制备的光学级金刚石, 采用金属-金刚石-金属结构研制了X射线金刚石探测器. 在8ps激光器上的探测器响应性能考核表明, 整个探测器系统的响应时间为444 ps, 上升时间为175 ps, 载流子寿命为285 ps. 将探测器应用于神光Ⅲ原型装置的内爆物理实验硬X射线测量, 分别测量得到以注入黑腔的激光转化为主和靶丸内爆产生为主的硬X射线能流, 测得的峰值信号分别正比于激光总能量和反比于靶丸CH层厚度.
    The diamond detector is used to diagnose X-ray and has the advantages of fast response, high sensitivity, large dynamic range, flat response, high breakdown field, and outstanding radiation hardness. The X-ray diamond detector with a metal-diamond-metal structur is developed, in which the optical grade diamond is synthesized by chemical vapor deposition (CVD) method. Through the calibration of response time on the pulse laser of 8 ps width, the full width at half maximum of the CVD diamond detector is 444 ps, the rise time of the detector is 175 ps, and the lifetime of the carrier is 285 ps. The detectors are used to measure the hard X-ray for the imploding experiment on SGIII-prototype equipment. The results indicate that the measured hard X-ray flux is produced mainly by laser and target imploding, and the peak signal is in direct proportion to the laser energy and in inverse proportion to the CH thickness of target.
    • 基金项目: 国家自然科学基金(批准号: 11205142)资助的课题.
    • Funds: Project supported by the National Natural Science Foundation of China (Grant No. 11205142).
    [1]

    Spielman R B 1992 Rev. Sci. Instrum. 63 5056

    [2]

    Turner R E, Landen O L, Bell P, Costa R, Hargrove D 1999 Rev. Sci. Instrum. 70 656

    [3]

    Hou L F, Li F, Yuan Y T, Yang G H, Liu S Y 2010 Acta Phys. Sin. 59 1137 (in Chinese) [侯立飞, 李芳, 袁永腾, 杨国洪, 刘慎业 2010 物理学报 59 1137]

    [4]

    Morse J, Salome M, Berdermann E, Pomorski M, Cunningham W, Grant J 2007 Diamond & Related Materials 16 1049

    [5]

    Bruzzi M, Menichelli D, Pini S, Bucciolini M, Molnar J, Fenyvesi A 2002 Appl. Phys. Lett. 81 298

    [6]

    MacPhee A G, Edgell D H, Bond E J, Bradley D K, Brown C G, Burns S R, Celeste J R, Cerjan C J, Eckart M J, Glebov V Y, Glenzer S H, Hey D H, Jones O S, Kilkenny J K, Kimbrough J R, Landen O L, Mackinnon A J, Meezan N B, Parker J M, Sweeney R M 2010 JINST 6 1

    [7]

    Wang L J, Liu J M, Su Q F, Shi W M, Xia Y B 2006 Acta Phys. Sin. 55 2518 (in Chinese) [王林君、刘建敏, 苏青峰, 史伟民, 夏义本 2006 物理学报 55 2518]

    [8]

    Schmid G J, Griffith R L, Izumi N, Koch J A, Lerche R A, Moran M J, Phillips T W, Turner R E, Glebov V Y, Sangster T C, Stoeckl C 2003 Rev. Sci. Instrum. 74 1828

    [9]

    Lei L, Ouyang X P, Cao N, Zhang X P, Wang L, Zhong Y H 2009 High Power Laser and Particle Beams 21 1083 (in Chinese) [雷岚, 欧阳晓平, 曹娜, 张显鹏, 王兰, 仲云红 2009 强激光与粒子束 21 1083]

    [10]

    Kania D R, Pan L S, Bell P, Landen O L, Kornblum H, Pianetta P, Perry M D 1990 J. Appl. Phys. 68 124

    [11]

    Knauer J P, Gindele N C 2004 Rev. Sci. Instrum. 75 3714

    [12]

    Dauffy L S, Koch J A 2005 LLNL Report No. UCRL-TR 216920

  • [1]

    Spielman R B 1992 Rev. Sci. Instrum. 63 5056

    [2]

    Turner R E, Landen O L, Bell P, Costa R, Hargrove D 1999 Rev. Sci. Instrum. 70 656

    [3]

    Hou L F, Li F, Yuan Y T, Yang G H, Liu S Y 2010 Acta Phys. Sin. 59 1137 (in Chinese) [侯立飞, 李芳, 袁永腾, 杨国洪, 刘慎业 2010 物理学报 59 1137]

    [4]

    Morse J, Salome M, Berdermann E, Pomorski M, Cunningham W, Grant J 2007 Diamond & Related Materials 16 1049

    [5]

    Bruzzi M, Menichelli D, Pini S, Bucciolini M, Molnar J, Fenyvesi A 2002 Appl. Phys. Lett. 81 298

    [6]

    MacPhee A G, Edgell D H, Bond E J, Bradley D K, Brown C G, Burns S R, Celeste J R, Cerjan C J, Eckart M J, Glebov V Y, Glenzer S H, Hey D H, Jones O S, Kilkenny J K, Kimbrough J R, Landen O L, Mackinnon A J, Meezan N B, Parker J M, Sweeney R M 2010 JINST 6 1

    [7]

    Wang L J, Liu J M, Su Q F, Shi W M, Xia Y B 2006 Acta Phys. Sin. 55 2518 (in Chinese) [王林君、刘建敏, 苏青峰, 史伟民, 夏义本 2006 物理学报 55 2518]

    [8]

    Schmid G J, Griffith R L, Izumi N, Koch J A, Lerche R A, Moran M J, Phillips T W, Turner R E, Glebov V Y, Sangster T C, Stoeckl C 2003 Rev. Sci. Instrum. 74 1828

    [9]

    Lei L, Ouyang X P, Cao N, Zhang X P, Wang L, Zhong Y H 2009 High Power Laser and Particle Beams 21 1083 (in Chinese) [雷岚, 欧阳晓平, 曹娜, 张显鹏, 王兰, 仲云红 2009 强激光与粒子束 21 1083]

    [10]

    Kania D R, Pan L S, Bell P, Landen O L, Kornblum H, Pianetta P, Perry M D 1990 J. Appl. Phys. 68 124

    [11]

    Knauer J P, Gindele N C 2004 Rev. Sci. Instrum. 75 3714

    [12]

    Dauffy L S, Koch J A 2005 LLNL Report No. UCRL-TR 216920

  • [1] 张少军, 郭智, 成加皿, 王勇, 陈家华, 刘志. 高重频硬X射线自由电子激光脉冲到达时间诊断方法研究. 物理学报, 2023, 72(10): 105203. doi: 10.7498/aps.72.20222424
    [2] 黄广伟, 吴坤, 陈晔, 李林祥, 张思远, 王尊刚, 朱红英, 周春芝, 张逸韵, 刘志强, 伊晓燕, 李晋闽. 单晶金刚石探测器对14 MeV单能中子的响应. 物理学报, 2021, 70(20): 202901. doi: 10.7498/aps.70.20210891
    [3] 张天奎, 于明海, 董克攻, 吴玉迟, 杨靖, 陈佳, 卢峰, 李纲, 朱斌, 谭放, 王少义, 闫永宏, 谷渝秋. 激光高能X射线成像中探测器表征与电子影响研究. 物理学报, 2017, 66(24): 245201. doi: 10.7498/aps.66.245201
    [4] 朱玥, 张子良, 杨彦佶, 薛荣峰, 崔苇苇, 陆波, 王娟, 陈田祥, 王于仨, 李炜, 韩大炜, 霍嘉, 胡渭, 李茂顺, 张艺, 祝宇轩, 刘苗, 赵晓帆, 陈勇. 硬X射线调制望远镜低能探测器量子效率标定. 物理学报, 2017, 66(11): 112901. doi: 10.7498/aps.66.112901
    [5] 陈直, 许良, 陈荣昌, 杜国浩, 邓彪, 谢红兰, 肖体乔. Kinoform单透镜的硬X射线聚焦性能. 物理学报, 2015, 64(16): 164104. doi: 10.7498/aps.64.164104
    [6] 王兰喜, 陈学康, 吴敢, 曹生珠, 尚凯文. 晶界对金刚石紫外探测器时间响应性能的影响. 物理学报, 2012, 61(3): 038101. doi: 10.7498/aps.61.038101
    [7] 赵学峰, 李三伟, 蒋刚, 王传珂, 李志超, 胡峰, 李朝光. 超热电子与金黑腔靶作用产生硬X射线的蒙特卡罗模拟. 物理学报, 2011, 60(7): 075203. doi: 10.7498/aps.60.075203
    [8] 周海洋, 朱晓东, 詹如娟. CVD金刚石辐射探测器研制及性能测试. 物理学报, 2010, 59(3): 1620-1624. doi: 10.7498/aps.59.1620
    [9] 侯立飞, 李芳, 袁永腾, 杨国洪, 刘慎业. 化学气相沉积金刚石探测器测量软X射线能谱. 物理学报, 2010, 59(2): 1137-1142. doi: 10.7498/aps.59.1137
    [10] 王可嘉, 刘劲松, 吕健滔. 双光子抽运随机激光器中辐射光能量的演化. 物理学报, 2007, 56(7): 3906-3910. doi: 10.7498/aps.56.3906
    [11] 王林军, 刘健敏, 苏青峰, 史伟民, 夏义本. 金刚石膜α粒子探测器的电学性能研究. 物理学报, 2006, 55(5): 2518-2522. doi: 10.7498/aps.55.2518
    [12] 欧阳晓平, 王 兰, 范如玉, 张忠兵, 王 伟, 吕反修, 唐伟忠, 陈广超. 金刚石膜探测器研制. 物理学报, 2006, 55(5): 2170-2174. doi: 10.7498/aps.55.2170
    [13] 黄万霞, 袁清习, 田玉莲, 朱佩平, 姜晓明, 王寯越. 同步辐射硬x射线衍射增强成像新进展. 物理学报, 2005, 54(2): 677-681. doi: 10.7498/aps.54.677
    [14] 于 斌, 彭 翔, 田劲东, 牛憨笨. 硬x射线同轴相衬成像的相位恢复. 物理学报, 2005, 54(5): 2034-2037. doi: 10.7498/aps.54.2034
    [15] 李荣斌, 戴永兵, 胡晓君, 沈荷生, 何贤昶. 能量粒子轰击金刚石的计算机模拟. 物理学报, 2003, 52(12): 3135-3141. doi: 10.7498/aps.52.3135
    [16] 刘存业, 刘 畅. CVD金刚石膜的结构分析. 物理学报, 2003, 52(6): 1479-1483. doi: 10.7498/aps.52.1479
    [17] 高大超, A.POGANY, A.W.STEVENSON, T.GUREYEV, S.W.WILKINS, 麦振洪. 硬X射线位相衬度成象. 物理学报, 2000, 49(12): 2357-2368. doi: 10.7498/aps.49.2357
    [18] 崔明启, 缪建伟, 王俊, 崔聪悟, 黎刚, 朱佩平. 软X射线多层膜单色器能量分辨研究. 物理学报, 1997, 46(5): 1015-1021. doi: 10.7498/aps.46.1015
    [19] 李晨曦, 陆坤权, 赵雅琴, 沈主同. 合成金刚石中金属Ni结构形态的扩展X射线吸收谱研究. 物理学报, 1990, 39(6): 19-24. doi: 10.7498/aps.39.19
    [20] 孙景文. X射线探测器的脉冲标定技术. 物理学报, 1986, 35(7): 864-873. doi: 10.7498/aps.35.864
计量
  • 文章访问数:  5898
  • PDF下载量:  500
  • 被引次数: 0
出版历程
  • 收稿日期:  2012-08-25
  • 修回日期:  2012-09-10
  • 刊出日期:  2013-03-05

/

返回文章
返回