明亮压缩态光场的操控及量子层析

CSTR: 32037.14.aps.70.20210318

Manipulations and quantum tomography of bright squeezed states

CSTR: 32037.14.aps.70.20210318
PDF
HTML
导出引用
  • 连续变量量子态的制备与操控是进行量子通信、量子密钥分发以及量子网络构建的重要基础. 本文基于二阶非线性过程, 利用周期极化磷酸氧钛钾晶体构成的简并光学参量放大腔, 在实验上实现了1064 nm波段明亮压缩态光场的制备, 所制备的明亮压缩态光场在泵浦光功率为310 mW、分析频率为3 MHz处的压缩度为–11.6 dB. 当注入50 mW泵浦光时, 实现了压缩度为–6 dB, 纯度为98.5%的压缩态光场; 在此基础上, 利用光电调制器进行明亮压缩态光场的线性光学操控, 并基于平衡零拍探测系统的直流信号准确判断压缩态光场时域信号对应的相位, 之后结合极大似然估计算法实现压缩态的量子层析, 得到量子态的密度矩阵及相空间的Wigner函数, 从而获得量子态的光子数分布等全部信息.

     

    Generation and manipulation of continuous variable quantum states are the building blocks of quantum communication, quantum key distribution and quantum networks. According to the second-order nonlinear process of the periodically-poled potassium titanyl phosphate (PPKTP) crystal, we design a semi-monolithic optical parametric amplifier (OPA) cavity to generate the bright squeezed light at a wavelength of 1064 nm. With the injection of a seed beam, the squeezed state generated by the OPA has a coherent amplitude, so called bright squeezed state. The squeezing level is directly observed to be –11.6 dB when the pump power is 310 mW at an analysis frequency of 3 MHz. However, with the increase of the pump power, the purity of the squeezed state gets lower and lower due to the increased influence of the anti-squeezing quadrature component on the squeezed quadrature component in the detection process. To obtain a higher purity of the squeezed state for achieving linear optical manipulation and quantum tomography, we choose the pump power of 50 mW, the squeezing level decreases to –6 dB, and the purity of the squeezed state is 98.5% in this case. An electro-optic modulator is adopted to realize the liner manipulation of the squeezed light in the phase space. During the measurement of the bright squeezed state, all the data are taken on condition that the length of the OPA cavity and relative phase between the seed beam and the pump beam are locked by a locking loop. The direct current (DC) signal of the balanced homodyne detection (BHD) is used to accurately determine the phase corresponding to the time domain signal of the squeezed state, while the alternate current (AC) signal of the BHD is mixed with the signal generated by the function generator, after passing through a low-pass filter and a high-pass filter, the signal is then amplified by using a low-noise amplifier. A high-performance oscilloscope is finally used to simultaneously collect the signals, thus obtaining the quantum noise signal of the bright squeezed light after linear manipulation. Together with the maximum likelihood estimation algorithm, the quantum tomography, the density matrix and the Wigner function of the bright squeezed light are obtained, that is, all the information such as the photon number distribution of the quantum state is determined. Multiple iterations are taken in the maximum likelihood estimation algorithm process to eliminate the influence of the low quantum efficiency on the detection system, so that the density matrix is fitted well with the theoretical results.

     

    目录

    /

    返回文章
    返回