搜索

x
中国物理学会期刊

双腔光力系统中基于连续域束缚态的超高分辨率质量传感

CSTR: 32037.14.aps.74.20250063

Ultrahigh-resolution mass sensing based on bound states in continuum domain in double-cavity optomechanical system

CSTR: 32037.14.aps.74.20250063
PDF
HTML
导出引用
  • 腔光力学质量传感器中分辨率是重要指标之一. 本文提出了一个基于连续域束缚态(bound states in the continuum, BIC)的超高分辨率质量传感方案. 该方案通过将光力学腔与辅助光学腔结合, 构建双腔光力系统, 利用BIC模式的高品质因子特性实现质量分辨率的显著提升. 在蓝失谐情况下, 该系统展现出类双光力诱导透明的现象, 相应的中间窄峰则表现为增益峰, 其线宽在光力协同性等于双光腔协同性加1时变为0, 对应形成BIC. 双腔光力系统中间透射峰的频率偏移量与振子频移成线性关系, 能实现对振子上吸附物的质量测量, 并且在BIC条件下其分辨率能达到ag量级. 此外, 对中间透射峰本征值的虚部和实部及其灵敏度增加因子的研究表明振子的频移对中间透射峰本征值的影响很小, 从而揭示出基于BIC的超高分辨率质量传感方案在频移影响下仍保持超高分辨率和精确的质量测量.

     

    Resolution is one of the key indicators in the cavity optomechanical mass sensing. The bound states in the continuum (BIC) enable extremely narrow linewidths, which have great potential for enhancing the resolution of cavity optomechanical mass sensors. In order to enhance the resolution of cavity optomechanical mass sensing, we propose a simple double-cavity optomechanical system under the blue-detuning condition to realize the BIC singularity, and present an ultrahigh-resolution mass sensing scheme based on BIC in this paper. By solving the linearized Heisenberg-Langevin equations, the expressions for the susceptibility and transmission rate of the system are derived. Based on the system’s susceptibility, we study the absorption characteristics of the probe field under the blue-detuning condition. The absorption spectrum of the system exhibits three peaks, among which the central narrow peak exhibits optical gain characteristics, collectively forming a phenomenon analogous to double optomechanically induced transparency. Then, analysis of the dressed-state energy-level structure reveals that the formation of the central narrow peak stems from quantum interference effects in a double-Λ-type dark-state resonance. The linewidth evolution of the quasi-BIC central narrow peak is investigated by analyzing the dependence of the real part and imaginary part of the corresponding eigenvalue on the optomechanical coupling strength. It can be found that the imaginary part of the eigenvalue for the central narrow peak becomes zero when the optomechanical cooperativity coefficient equals the double-cavity cooperativity coefficient plus one, enabling the realization of BIC. The linewidth of the central peak is ultrasmall under this BIC condition, and the shift of the transmission peak in the transmission spectrum is linearly related to the adsorbed mass. Based on these characteristics, the system under the BIC condition can achieve mass sensing with an ultrahigh resolution, with a resolution of approximately 1 ag. Meanwhile, the linewidth of the transmission peak can be suppressed below 1 Hz, which is superior to the traditional optomechanical mass sensing schemes based on four-wave mixing, photonic molecules, and plasmon polaritons. Systematic investigation of eigenvalue variations and the corresponding sensitivity enhancement factors under mechanical resonator frequency shift reveals that the real part and the imaginary part of the eigenvalue associated with the central peak exhibit negligible variations under such perturbations. This indicates that the mass sensing scheme based on BIC in the double-cavity optomechanical system can maintain ultrahigh resolution and precise mass measurement under mechanical resonator frequency shift. Our scheme provides an approach for realizing the BIC singularity in optomechanical systems, and presents a new route to improving the resolution of mass sensors based on cavity optomechanical systems.

     

    目录

    /

    返回文章
    返回