搜索

x
中国物理学会期刊

国家授时中心冷原子光晶格钟NTSC-Sr2的研制和绝对频率测量

Development and absolute-frequency measurement of the NTSC-Sr2 cold-atom strontium optical lattice clock

PDF
导出引用
  • 本文系统介绍中国科学院国家授时中心冷原子锶光晶格钟(NTSC-Sr2)的研制、系统评估及新增绝对频率测量结果。针对黑体辐射频移、晶格光交流斯塔克频移、原子隧穿和直流斯塔克频移等限制中性原子光钟准确度的主要因素,研制了带主动温控的铜质黑体辐射屏蔽腔、可移动浅光晶格和真空内导电屏蔽结构等。激光冷却后的87Sr原子由移动光晶格输运约17 mm进入温度稳定在273.15 K附近的屏蔽腔,在39.8 ER工作阱深下进行钟跃迁探测。通过交替自比对技术得到单钟稳定度为3.6×10-16 (τ/s)-1/2。系统评估给出总频移不确定度2.0×10-18。在连续一年的光钟溯源国际原子时数据基础上,新增Circular T 461、462和464三个测量月,累计纳入15个月数据,平均运行率为28.3%,测得87Sr 1S0-3P0跃迁绝对频率为429 228 004 229 872.97(6) Hz,相对不确定度1.5×10-16。上述结果表明,NTSC-Sr2已形成从装置运行、系统频移评估到SI秒溯源的完整测量能力,可为国际原子时校准和秒定义变更提供独立数据。

     

    We report the development, systematic evaluation, and extended absolute-frequency measurement of the NTSC-Sr2 strontium optical lattice clock at the National Time Service Center. Laser-cooled 87Sr atoms are transported by a movable one-dimensional optical lattice over 17.29 mm into a copper blackbody-radiation shield stabilized near 273.15 K. Clock spectroscopy is performed at a lattice depth of 39.8 ER. A 400 ms Rabi interrogation produces a 2.5 Hz linewidth, close to the Fourier limit. Interleaved locking of two digital servos to the same atomic transition gives an equivalent single-servo fractional-frequency instability of 3.6 × 10-16(τ/s)-1/2. Because the two servos share the atomic preparation, trapping and detection sequence, as well as the clock laser, this result characterizes the short-term servo and detection performance rather than an independent comparison between two clocks. The evaluated fractional systematic correction is −3707.5 × 10-18 with a total uncertainty of 2.0 × 10-18; the dominant contribution is the lattice-light Stark shift, with an uncertainty of 1.6 × 10-18, followed by the blackbody-radiation contribution of 0.7 × 10-18. For the absolute-frequency measurement, NTSC-Sr2 is linked to the SI second through HM085, UTC(NTSC), and International Atomic Time. Three additional Circular T intervals (461, 462, and 464) extend the previously reported one-year campaign to 15 measurement months, with a mean uptime of 28.3% and approximately 3.1 × 103 hour of valid data. The weighted frequency of the 87Sr 1S0–3P0 transition is 429 228 004 229 872.97(6) Hz, corresponding to a relative uncertainty of 1.5 × 10-16. These results establish an end-to-end capability encompassing clock operation, systematic-shift evaluation, and SI-traceable absolute-frequency measurement, and provide an independent data set for optical-clock contributions to international time-scale calibration and the future redefinition of the second.

     

    目录

    /

    返回文章
    返回