Search

Article

x

留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

Effect of pile-up of electron flow pulse from photomultiplier tube on ranging by photon counting

Xiang Yu-Yan Li Song Ma Yue

Citation:

Effect of pile-up of electron flow pulse from photomultiplier tube on ranging by photon counting

Xiang Yu-Yan, Li Song, Ma Yue
PDF
HTML
Get Citation
  • Photomultiplier tube (PMT) features single photon level sensitivity, low dark count, and low afterpulse probability, and are widely used in photon-counting lidar in the visible spectrum. The PMT has no photon detection dead time, for every photon it responds to, it can output an electron flow pulse, these pulses of electron flow are likely to pile up into larger pulses. When using threshold identification method to identify photon-events, the stacked pulse will introduce additional pulse walking error, directly affecting the ranging precision of photon-counting ranging method in the practical application of laser ranging. Considering the influence of pulse pile-up, a new theoretical model of PMT photon detection is established to describe the influence of pulse pile-up on the detection probability of photon-events by analyzing the relationship between the detection time of photon and the identification time of the PMT final output photon-events. Through Monte Carlo simulation, the relationship among the ranging walking error, ranging accuracy, incident laser pulse width, PMT output electron flow pulse width and photon-events identification threshold is obtained. In order to verify the correctness of the theory, a PMT-based photon-counting lidar system is built. The comparative experiment with GM-APD proves that the influence of pulse pile-up on PMT photon-counting ranging method cannot be ignored, and that the experimental results are in good agreement with results from the theoretical model. The PMT photon detection model based on pulse pile-up can guide the design of PMT photon-counting radar and improve the ranging accuracy and precision of the ranging system.
      Corresponding author: Li Song, ls@whu.edu.cn
    [1]

    Degnan J 2016 Remote Sens. 8 958Google Scholar

    [2]

    Massa J S, Wallace A M, Buller G S, Fancey S J, Walker A C 1997 Opt. Lett. 22 543Google Scholar

    [3]

    Kirmani A, Venkatraman D, Shin D, Colaco A, Wong F N C, Shapiro J H, Goyal V K 2014 Science 343 58Google Scholar

    [4]

    Maccarone A, McCarthy A, Ren X, Warburton R E, Wallace A M, Moffat J, Petillot Y, Buller G S 2015 Opt. Express 23 33911Google Scholar

    [5]

    Li Z, Lai J, Wang C, Yan W, Li Z 2017 Appl. Opt. 56 6680Google Scholar

    [6]

    Akiba M, Inagaki K, Tsujino K 2012 Opt. Express 20 2779Google Scholar

    [7]

    Ravil A 2018 Appl. Opt. 57 3679Google Scholar

    [8]

    Kitsmiller V J, Campbell C, O'Sullivan T D 2020 Biomed. Opt. Express 11 5373Google Scholar

    [9]

    Jones R, Oliver C, Pike E R 1971 Appl. Opt. 10 1673Google Scholar

    [10]

    McGill M, Markus T, Scott V. S, Neumann T 2013 J. Atmos. Oceanic Technol. 30 345Google Scholar

    [11]

    Abdalati W, Zwally H. J, Bindschadler R, Csatho B, Farrell S L, Fricker H A, Harding D, Kwok R, Lefsky M, Markus T, Marshak A, Neumann T, Palm S, Schutz B, Smith B, Spinhirne J, Webb C, 2010 Proc. IEEE 98 735Google Scholar

    [12]

    Markus T, Neumann T, Martino A, Abdalati W, Brunt K, Csatho B, Farrell S, Fricker H, Gardner A, Harding D, Jasinski M, Kwok R, Magruder L, Lubin D, Luthcke S, Morison J, Nelson R, Neuenschwander A, Palm S, Popescu S, Shum C, B. Schutz E, Smith B, Yang Y, Zwally J 2017 Remote Sens. Environ. 190 260Google Scholar

    [13]

    Helstrom C W 1984 J. Appl. Phys. 55 2786Google Scholar

    [14]

    Ingle J D, Crouch S R 1972 Anal. Chem. 44 777Google Scholar

    [15]

    谢庚承, 叶一东, 李建民, 袁学文 2018 中国激光 45 260Google Scholar

    Xie G C, Ye Y D, Li J M, Yuan X W 2018 Chinese Journal of Lasers 45 260Google Scholar

    [16]

    Donovan D P, Whiteway J A, Carswell I A 1993 Appl. Opt. 32 6742Google Scholar

    [17]

    Chen Z D, Li X D, Li X H, Ye G C, Zhou Z G 2019 Opt. Commun. 434 7Google Scholar

    [18]

    Zhang Z Y, Li S, Ma Y, Zhang W H, Zhao P F, Xiang Y Y 2020 Optics Express. 28 13586Google Scholar

    [19]

    Gatt P, Johnson S, Nichols T 2009 Appl. Opt. 48 3261Google Scholar

    [20]

    Li S, Zhang Z, Ma Y, Zeng H M, Zhao P F, Zhang W H 2019 Opt. Express 27 A861Google Scholar

    [21]

    White Book of Photomultiplier Tubes, Hamamatsu Photonics http://share.hamamatsu.com.cn/57f4441b72a94d8a91500e56afad0b7b/download.html [2022-07-18]

    [22]

    黄科, 李松, 马跃, 田昕, 周辉, 张智宇 2018 物理学报 67 064205Google Scholar

    Huang K, Li S, Ma Y, Tian X, Zhou H, Zhang Z Y 2018 Acta Phys. Sin. 67 064205Google Scholar

  • 图 1  PMT输出电子流脉冲叠加对光子事件鉴别的影响

    Figure 1.  Influence of PMT output electron flow pulse pile-up on photon-events discrimination.

    图 2  (a) 回波光子数为1时, PMT光子事件鉴别时间与电子流脉冲峰值时间存在系统误差$ \gamma $; (b)蓝色曲线和橙色曲线分别为PMT响应$ {\mu _1} $, $ {\mu _2} $时刻到达的光子输出的电子流脉冲, 黄色曲线为两个脉冲的叠加, $ {w_{\left( {{\mu _1}, {\mu _2}} \right)}} $$ {\mu _1} $, $ {\mu _2} $时刻的电子流脉冲叠加产生的脉冲行走误差

    Figure 2.  (a) When the number of incident photons is 1, there is a systematic error $ \gamma $ between the PMT photon-events identification time and the peak time of electron flow pulse; (b) the blue curve and the orange curve are the electron flow pulses output responsed by PMT for the photon arriving at time $ {\mu _1} $ and $ {\mu _2} $ respectively. The yellow curve is the pile-up of two pulses, and $ {w_{\left( {{\mu _1}, {\mu _2}} \right)}} $ is the pulse walk error generated by the pile-up of the tow electron flow pulses at time $ {\mu _1} $ and $ {\mu _2} $.

    图 3  PMT单光子探测模型与传统单光子探测模型概率分布的区别 (a) Ns = 0.5; (b) Ns = 2; (c) Ns = 4; (d) Ns = 10

    Figure 3.  Difference of probability distribution between PMT single-photon detection model and traditional single-photon detection model: (a) Ns = 0.5; (b) Ns = 2; (c) Ns = 4; (d) Ns = 10.

    图 4  PMT单光子探测模型和传统单光子探测模型关于测距行走误差Ra和测距精度 Rp的比较

    Figure 4.  Comparison between PMT single-photon detection model and traditional single-photon detection model on ranging walking error Ra and ranging accuracy Rp.

    图 5  不同电子流高斯脉宽$ {\delta _{\text{p}}} $条件下PMT探测模型测距行走误差Ra和测距精度 Rp与入射信号光子数的关系

    Figure 5.  Relationship of ranging walk error Ra and ranging accuracy Rp of PMT detection model to incident signal photon number under different Gaussian pulse width $ {\delta _{\text{p}}} $ of electron flow.

    图 6  PMT探测模型测距行走误差Ra和测距精度 Rp与光子事件鉴别阈值$ {T_{\text{h}}} $的关系

    Figure 6.  Relationship of the ranging walking error Ra and ranging accuracy Rp of the PMT detection model to the identification threshold of photon-events

    图 7  光子计数雷达系统示意图

    Figure 7.  Schematic of the photon-counting radar system.

    图 8  (a)无射频放大器光子事件鉴别电路; (b)带射频放大器光子事件鉴别电路

    Figure 8.  (a) Photon-events identification circuit without RF amplifier; (b) photon-events identification circuit with RF amplifier.

    图 9  (a) PMT输出脉冲归一化幅值与平均入射信号光子数的关系; (b) APD测得的回波信号脉冲

    Figure 9.  (a) Relationship between PMT output pulse normalized amplitude and average number of incident signal photon; (b) incident signal pulse measured by APD.

    图 10  (a)带RF放大器的PMT探测概率分布随入射信号光子数的变化; (b)不带RF放大器的PMT探测概率分布随入射信号光子数的变化; (c) GM-APD探测概率分布随入射信号光子数的变化

    Figure 10.  (a) Experimental results of PMT detection probability distribution with RF amplifier varying with the number of incident signal photons; (b) experimental results of PMT detection probability distribution without RF amplifier varying with the number of incident signal photons; (c) experimental results of GM-APD detection probability distribution varying with the number of incident signal photons.

    图 11  (a)带RF放大器的PMT探测概率分布随入射信号光子数的变化仿真实验结果; (b)不带RF放大器的PMT探测概率分布随入射信号光子数的变化仿真实验结果

    Figure 11.  (a) Simulation results of PMT detection probability distribution with RF amplifier varying with photon number of incident signal; (b) simulation results of PMT detection probability distribution without RF amplifier varying with photon number of incident signal.

    图 12  三种探测器的测距行走误差的仿真模型和实验数据对比, 橙色实线为GM-APD的Ra理论探测曲线, 橙色“+”为GM-APD的Ra实验数据点; 蓝色实线为不带放大器PMT的Ra理论探测曲线, 蓝色“o”为不带RF放大器的PMT的 Ra实验数据点; 黄色实线为带RF放大器PMT的Ra理论探测曲线, 黄色“x”为带RF放大器PMT的Ra实验数据点

    Figure 12.  Comparison of the simulation model and experimental data of the ranging walking error of the three detectors. The solid orange line is the Ra theoretial curve of GM-APD, and the orange “+” is the Ra experimental data point of GM-APD. The blue solid line is the Ra theoretial curve of PMT without RF amplifier, and the blue “o” is the Ra experimental data point of PMT without RF amplifier. The solid yellow line is Ra theoretial curve of PMT with RF amplifier, and the yellow “x” is Ra experimental data point of PMT with RF amplifier.

    表 1  PMT和GM-APD模块性能参数

    Table 1.  Parameters of PMT and GM-APD module

    探测器PMTGM-APD
    增益106—107105—106
    探测效率(640 nm)/%1820
    暗计数(counts)<30<500
    探测死区时间/ns2050
    时间抖动/ps<200<500
    DownLoad: CSV
  • [1]

    Degnan J 2016 Remote Sens. 8 958Google Scholar

    [2]

    Massa J S, Wallace A M, Buller G S, Fancey S J, Walker A C 1997 Opt. Lett. 22 543Google Scholar

    [3]

    Kirmani A, Venkatraman D, Shin D, Colaco A, Wong F N C, Shapiro J H, Goyal V K 2014 Science 343 58Google Scholar

    [4]

    Maccarone A, McCarthy A, Ren X, Warburton R E, Wallace A M, Moffat J, Petillot Y, Buller G S 2015 Opt. Express 23 33911Google Scholar

    [5]

    Li Z, Lai J, Wang C, Yan W, Li Z 2017 Appl. Opt. 56 6680Google Scholar

    [6]

    Akiba M, Inagaki K, Tsujino K 2012 Opt. Express 20 2779Google Scholar

    [7]

    Ravil A 2018 Appl. Opt. 57 3679Google Scholar

    [8]

    Kitsmiller V J, Campbell C, O'Sullivan T D 2020 Biomed. Opt. Express 11 5373Google Scholar

    [9]

    Jones R, Oliver C, Pike E R 1971 Appl. Opt. 10 1673Google Scholar

    [10]

    McGill M, Markus T, Scott V. S, Neumann T 2013 J. Atmos. Oceanic Technol. 30 345Google Scholar

    [11]

    Abdalati W, Zwally H. J, Bindschadler R, Csatho B, Farrell S L, Fricker H A, Harding D, Kwok R, Lefsky M, Markus T, Marshak A, Neumann T, Palm S, Schutz B, Smith B, Spinhirne J, Webb C, 2010 Proc. IEEE 98 735Google Scholar

    [12]

    Markus T, Neumann T, Martino A, Abdalati W, Brunt K, Csatho B, Farrell S, Fricker H, Gardner A, Harding D, Jasinski M, Kwok R, Magruder L, Lubin D, Luthcke S, Morison J, Nelson R, Neuenschwander A, Palm S, Popescu S, Shum C, B. Schutz E, Smith B, Yang Y, Zwally J 2017 Remote Sens. Environ. 190 260Google Scholar

    [13]

    Helstrom C W 1984 J. Appl. Phys. 55 2786Google Scholar

    [14]

    Ingle J D, Crouch S R 1972 Anal. Chem. 44 777Google Scholar

    [15]

    谢庚承, 叶一东, 李建民, 袁学文 2018 中国激光 45 260Google Scholar

    Xie G C, Ye Y D, Li J M, Yuan X W 2018 Chinese Journal of Lasers 45 260Google Scholar

    [16]

    Donovan D P, Whiteway J A, Carswell I A 1993 Appl. Opt. 32 6742Google Scholar

    [17]

    Chen Z D, Li X D, Li X H, Ye G C, Zhou Z G 2019 Opt. Commun. 434 7Google Scholar

    [18]

    Zhang Z Y, Li S, Ma Y, Zhang W H, Zhao P F, Xiang Y Y 2020 Optics Express. 28 13586Google Scholar

    [19]

    Gatt P, Johnson S, Nichols T 2009 Appl. Opt. 48 3261Google Scholar

    [20]

    Li S, Zhang Z, Ma Y, Zeng H M, Zhao P F, Zhang W H 2019 Opt. Express 27 A861Google Scholar

    [21]

    White Book of Photomultiplier Tubes, Hamamatsu Photonics http://share.hamamatsu.com.cn/57f4441b72a94d8a91500e56afad0b7b/download.html [2022-07-18]

    [22]

    黄科, 李松, 马跃, 田昕, 周辉, 张智宇 2018 物理学报 67 064205Google Scholar

    Huang K, Li S, Ma Y, Tian X, Zhou H, Zhang Z Y 2018 Acta Phys. Sin. 67 064205Google Scholar

  • [1] Liang Xu, Lin Jia-Rui, Wu Teng-Fei, Zhao Hui, Zhu Ji-Gui. Absolute distance measurement using cross correlation interferometer with a repetition rate multiplication frequency comb. Acta Physica Sinica, 2022, 71(9): 090602. doi: 10.7498/aps.71.20212073
    [2] Wu Feng-Chuan, Lin Yi, Wu Bo, Fu Yun-Qi. Response characteristics of radio frequency pulse of Rydberg atoms. Acta Physica Sinica, 2022, 71(20): 207402. doi: 10.7498/aps.71.20220972
    [3] Wang Chong, Dang Wen-Bin, Zhu Bing-Li, Yang Kai, Yang Jia-Hao, Han Jiang-Hao. Method of compensating for time measurement error of photomultiplier tube. Acta Physica Sinica, 2022, 71(22): 222901. doi: 10.7498/aps.71.20221193
    [4] Yuyan Xiang,  Li song,  Ma yue. Effect of PMT output electron flow pulse pile-up on photon counting ranging method. Acta Physica Sinica, 2022, 0(0): . doi: 10.7498/aps.7120220537
    [5] Wu Chen-Yi, Wang Lin-Li, Shi Hao-Tian, Wang Yu-Rong, Pan Hai-Feng, Li Zhao-Hui, Wu Guang. Single-photon ranging with hundred-micron accuracy. Acta Physica Sinica, 2021, 70(17): 174201. doi: 10.7498/aps.70.20210184
    [6] Peng Bo, Qu Xing-Hua, Zhang Fu-Min, Zhang Tian-Yu, Zhang Tie-Li, Liu Xiao-Xu, Xie Yang. Absolute distance measurement based on asymmetric cross-correlation of femtosecond pulse. Acta Physica Sinica, 2018, 67(21): 210601. doi: 10.7498/aps.67.20181274
    [7] Huang Min-Shuang, Ma Peng, Liu Xiao-Chen. Multi-pulse laser ranging method for pre-detection with high frequency resonance. Acta Physica Sinica, 2018, 67(7): 074202. doi: 10.7498/aps.67.20172079
    [8] Cao Hui, Song You-Jian, Yu Jia-He, Shi Hao-Sen, Hu Ming-Lie, Wang Qing-Yue. Singular spectrum analysis for precision improvement in dual-comb laser ranging. Acta Physica Sinica, 2018, 67(1): 010601. doi: 10.7498/aps.67.20171922
    [9] Wang Dong, Guo Liang-Hao, Liu Jian-Jun, Qi Yu-Bo. Passive impulsive source range estimation based on warping operator in shallow water. Acta Physica Sinica, 2016, 65(10): 104302. doi: 10.7498/aps.65.104302
    [10] Xu Xiao-Bin, Zhang He, Zhang Xiang-Jin, Chen Shan-Shan, Zhang Wei. Effect of plane target characteristics on ranging distribution for pulse laser detection. Acta Physica Sinica, 2016, 65(21): 210601. doi: 10.7498/aps.65.210601
    [11] Zhang Sen, Tao Xu, Feng Zhi-Jun, Wu Gan-Hua, Xue Li, Yan Xia-Chao, Zhang La-Bao, Jia Xiao-Qing, Wang Zhi-Zhong, Sun Jun, Dong Guang-Yan, Kang Lin, Wu Pei-Heng. Enhanced laser ranging with superconducting nanowire single photon detector for low dark count rate. Acta Physica Sinica, 2016, 65(18): 188501. doi: 10.7498/aps.65.188501
    [12] Guo Le-Hui, Tian Jin-Shou, Lu Yu, Li Hong-Wei. Optimization of the 3-inch photomultiplier tube for the neutrino detection. Acta Physica Sinica, 2016, 65(22): 228501. doi: 10.7498/aps.65.228501
    [13] Kou Tian, Wang Hai-Yan, Wang Fang, Wu Xue-Ming, Wang Ling, Xu Qiang. Ranging characteristic and uncertainty of airborne multi-pulse laser. Acta Physica Sinica, 2015, 64(12): 120601. doi: 10.7498/aps.64.120601
    [14] Zhang Jun-Long, Yang Liang, Yan Hui-Jie, Hua Yue, Ren Chun-Sheng. Influence of discharge parameters on blow-by in a coaxial plasma gun. Acta Physica Sinica, 2015, 64(7): 075201. doi: 10.7498/aps.64.075201
    [15] Qin Peng, Chen Wei, Song You-Jian, Hu Ming-Lie, Chai Lu, Wang Ching-Yue. Long range absolute distance measurement based on femtosecond laser balanced optical cross-correlation. Acta Physica Sinica, 2012, 61(24): 240601. doi: 10.7498/aps.61.240601
    [16] Wang Qian-Qian, Wei Guang-Hui. . Acta Physica Sinica, 2002, 51(5): 1031-1034. doi: 10.7498/aps.51.1031
    [17] WANG SHOU-MIN. THE INVESTIGATION OF THE TIME RESOLUTION CHARACTERISTICS OF A PHOTOMULTIPLIER. Acta Physica Sinica, 1962, 18(11): 600-604. doi: 10.7498/aps.18.600
    [18] СЧЁТЧИКИ С УПРАВЛЯЕМЫМ ИМПУЛЬСНЫМ ПИТАНИЕМ (Ⅱ). Acta Physica Sinica, 1961, 17(7): 340-352. doi: 10.7498/aps.17.340
    [19] СЧЁТЧИКИ С УПРАВЛЯЕМЫМ ИМПУЛЬСНЫМ ПИТАНИЕМ(Ⅲ). Acta Physica Sinica, 1961, 17(9): 430-438. doi: 10.7498/aps.17.430
    [20] СЧЁТЧИКИ С УПРАВЛЯЕМЫМ ИМПУПЬСНЫМ ПИТАНИЕМ(Ⅰ). Acta Physica Sinica, 1961, 17(6): 273-286. doi: 10.7498/aps.17.273
Metrics
  • Abstract views:  2385
  • PDF Downloads:  52
  • Cited By: 0
Publishing process
  • Received Date:  24 March 2022
  • Accepted Date:  21 July 2022
  • Available Online:  19 October 2022
  • Published Online:  05 November 2022

/

返回文章
返回