  • 研制了用于脉冲星导航的X射线光子计数探测器原理样机, 该探测器主要由对X射线灵敏度较高的CsI光电阴极、微通道板电子倍增器和收集阳极组成. 对X射线光子计数探测器灵敏度、时间分辨率和整个系统的死时间进行了测试, 实验结果表明该探测器的灵敏度在5 keV时可达5.2× 103 A/W, 时间分辨率可达到1.1 ns, 系统整体的死时间为100 ns.
    [1]

    Sheikh S I, Pines D J, Ray P S, Wood K S, Lovellette M N, Wolff M T 2004 Proceedings of 14th AAS/AIAA Space Flight Mechanics Conference Maui, HI, February 8–12, 2004 p105

    [2]

    Sheikh S I, Pines D J 2006 J. Guid. Contr. Dyn. 29 49

    [3]

    Zhang X H, Zhao B S, Liu Y A, Miao Z H, Zhu X P, Zhao F F 2009 Acta Phys. Sin. 58 1779 (in Chinese) [张兴华, 赵宝升, 刘永安, 繆震华, 朱香平, 赵菲菲 2009 物理学报 58 1779]

    [4]

    Zhang X H, Zhao B S, Miao Z H, Zhu X P, Liu Y A, Zou W 2008 Acta Phys. Sin. 57 4238 (in Chinese) [张兴华, 赵宝升, 繆震华, 朱香平, 刘永安, 邹玮 2008 物理学报 57 4238]

    [5]

    Grande M, Maddison B J, Howe C J, Kellett B J 2009 Planet. Space Sci. 57 717

    [6]

    Rideout R M, Pearson J F, Fraser G W, Lees J E, Brunton A N, Bannister N P, Kenter A T, Kraft R P 1998 Proc. SPIE 3445 384

    [7]

    Hu H J, Zhao B S, Sheng L Z, Yan Q R 2011 Acta Phys. Sin. 60 029701 (in Chinese) [胡慧君, 赵宝升, 盛立志, 鄢秋荣 2011 物理学报 60 029701]

    [8]

    Yang T G 2008 Chin. J. Space Sci. 28 330 (in Chinese) [杨廷高 2008 空间科学学报 28 330]

    [9]

    Taylor J H 1991 Proc. IEEE 79 1054

    [10]

    Wu Z H 1997 Atomic Nucleus Physics Experiment Method (3) (Beijing: Atomic Energy Press) p22 (in Chinese) [吴治华 1997 原子核物理实验方法 (3) (北京: 原子能出版社) 第22页]

  • [1]

    Sheikh S I, Pines D J, Ray P S, Wood K S, Lovellette M N, Wolff M T 2004 Proceedings of 14th AAS/AIAA Space Flight Mechanics Conference Maui, HI, February 8–12, 2004 p105

    [2]

    Sheikh S I, Pines D J 2006 J. Guid. Contr. Dyn. 29 49

    [3]

    Zhang X H, Zhao B S, Liu Y A, Miao Z H, Zhu X P, Zhao F F 2009 Acta Phys. Sin. 58 1779 (in Chinese) [张兴华, 赵宝升, 刘永安, 繆震华, 朱香平, 赵菲菲 2009 物理学报 58 1779]

    [4]

    Zhang X H, Zhao B S, Miao Z H, Zhu X P, Liu Y A, Zou W 2008 Acta Phys. Sin. 57 4238 (in Chinese) [张兴华, 赵宝升, 繆震华, 朱香平, 刘永安, 邹玮 2008 物理学报 57 4238]

    [5]

    Grande M, Maddison B J, Howe C J, Kellett B J 2009 Planet. Space Sci. 57 717

    [6]

    Rideout R M, Pearson J F, Fraser G W, Lees J E, Brunton A N, Bannister N P, Kenter A T, Kraft R P 1998 Proc. SPIE 3445 384

    [7]

    Hu H J, Zhao B S, Sheng L Z, Yan Q R 2011 Acta Phys. Sin. 60 029701 (in Chinese) [胡慧君, 赵宝升, 盛立志, 鄢秋荣 2011 物理学报 60 029701]

    [8]

    Yang T G 2008 Chin. J. Space Sci. 28 330 (in Chinese) [杨廷高 2008 空间科学学报 28 330]

    [9]

    Taylor J H 1991 Proc. IEEE 79 1054

    [10]

    Wu Z H 1997 Atomic Nucleus Physics Experiment Method (3) (Beijing: Atomic Energy Press) p22 (in Chinese) [吴治华 1997 原子核物理实验方法 (3) (北京: 原子能出版社) 第22页]

  • 引用本文:
    Citation:
计量
  • 文章访问数:  3067
  • PDF下载量:  585
  • 被引次数: 0
出版历程
  • 收稿日期:  2011-03-21
  • 修回日期:  2011-04-02
  • 刊出日期:  2012-01-05

用于脉冲星导航的X射线光子计数探测器研究

  • 1. 中国科学院西安光学精密机械研究所瞬态光学与光子技术国家重点实验室, 西安 710119;
  • 2. 中国科学院研究生院, 北京 100049

摘要: 研制了用于脉冲星导航的X射线光子计数探测器原理样机, 该探测器主要由对X射线灵敏度较高的CsI光电阴极、微通道板电子倍增器和收集阳极组成. 对X射线光子计数探测器灵敏度、时间分辨率和整个系统的死时间进行了测试, 实验结果表明该探测器的灵敏度在5 keV时可达5.2× 103 A/W, 时间分辨率可达到1.1 ns, 系统整体的死时间为100 ns.

English Abstract

参考文献 (10)

目录

    /

    返回文章
    返回