用計數器法直接測定錒系對於 鈾鐳系之分枝比例

鄭大章 楊永宗

引用本文:
Citation:

用計數器法直接測定錒系對於 鈾鐳系之分枝比例

鄭大章, 楊永宗

On the Determination of The Branching Ratio of The Actinium Series Relative to The Uranium-Radium Series By A Direct Counting Method

Teheng Da-Tehang, Yang Jeng-Tsong
PDF
导出引用
  • 本文主旨,在申述用蓋革計數器直接測定錒系對於鈾鐳系之分枝比例之經過,共中包括用磷酸鋯與用氯化鈦二法從巳成放射平衡之礦石中提取原錒,用釙之放射測定計數器之效率,然後數計一定量之原錒放射α質點之速度諸手續;以此速度與原來礦石中所合相當鈾量放射α質點之速度相比,卽得此二系間之分枝比例。
    作者用上開二化學方法提取之原錒測定分枝比例之結果,平均值為3.969%,與前人用游離室法测定之值4%較,殊相符合;尤以用氦化鈦法提取原鋼之結果,與用磷酸鋯法相近,足證前者公提取原錒之良媒,一如後者也。
    The branching ratio between actinium series and uraniumradium series has been redetermined direetly by means of a counter.The procedure consists in the extraction of protactinium by zirconium phosphate and by titanium oxide from a known uranium mineral,the determination of the efficiency of the counter by means of polonium,and the counting of a-partieles emitted by a known quantity of protactinium preparation. The number of a-particles counted is compared with that caleulated from the uranium contained in the same quantity of mineral. The ratio between them gives the branehing ratio between the two series. The mean value of the ratio obtained with both method of ex-traction is 3,969%,in kood agreement with the value 4% abtained by most predecessors using indirect ionization method. The results obtained by using titanium oxide closely confirms that obtained by using zireonium phosphate,which means that the former is as good an extractant of protactinium as the latter.