Analysis on quantum bit error rate in measurement-device-independent quantum key distribution using weak coherent states

Du Ya-Nan Xie Wen-Zhong Jin Xuan Wang Jin-Dong Wei Zheng-Jun Qin Xiao-Juan Zhao Feng Zhang Zhi-Ming

Citation:

Analysis on quantum bit error rate in measurement-device-independent quantum key distribution using weak coherent states

Du Ya-Nan, Xie Wen-Zhong, Jin Xuan, Wang Jin-Dong, Wei Zheng-Jun, Qin Xiao-Juan, Zhao Feng, Zhang Zhi-Ming
PDF
Get Citation

(PLEASE TRANSLATE TO ENGLISH

BY GOOGLE TRANSLATE IF NEEDED.)

  • A measurement-device-independent quantum key distribution (MDI-QKD) protocol is immune to all detection side-channel attacks and guarantees the information-theoretical security even with uncharacterized single photon detectors. A weak coherent source is used in the current MDI-QKD experiments, it inevitably contains a certain percentage of vacuum and multi-photon pulses. The security issues introduced by these source imperfections can be avoided by applying the decoy state method. Here, through modeling experimental devices, and taking into account the weak coherent source and the threshold detectors, we have evaluated the gain, the probability to get successful Bell measurement and incorrect Bell measurement, and the quantum bit error rate (QBER), given a practical setup. In our simulation, we show how QBER varies with different transmission distances in the cases when the average photon numbers per pulse from Alice and Bob are symmetric and asymmetric. Result shows that the multi-photon pulses do not cause error in the Z basis of polarization encoding scheme, but produce a large QBER in phase encoding scheme and in the X basis of polarization encoding scheme. QBER is affected by the dark count rate and the system optical error associated with the multi-photon pulses. For different encoding schemes, QBER caused by each kind of average photon numbers from Alice and Bob increases to different degrees with the transmission distance, and finally is close to 50%. With the increase of the transmission distance, the average photon number per pulse decreases and the fraction of the dark count rate causing QBER gradually increases. Under the same effect of the dark count rate, the smaller the average photon number per pulse, the bigger the QBER. After a certain transmission and at the same transmission distance, the QBER is largest when average photon numbers used by Alice and Bob are both smallest. For the short distance transmission of phase encoding scheme and the X basis, we find that QBER is larger when average photon numbers from the two arms are asymmetric, as compared to the symmetric case. For the Z basis, the QBER caused by the system optical error and the dark count rate is very small.
    • Funds: Project supported by the National Natural Science Foundation of China (Grant Nos. 61378012, 61401262, 11374107), the Major Research Plan of the National Natural Science Foundation of China(Grant No. 91121023), the National Basic Research Program of China (Grant Nos. 2011CBA00200, 2013CB921804), the Program for Changjiang Scholars and Innovative Research Team in University of Ministry of Education of China (Grant No. IRT1243), and the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20124407110009).
    [1]

    Gisin N, Ribordy G, Tittel W, Zbinden H 2002 Rev. Mod. Phys. 74 145

    [2]

    Li M, Patcharapong T, Zhang C M, Yin Z Q, Chen W, Han Z F 2015 Chin. Phys. B 24 010302

    [3]

    Ma H Q, Wei K J, Yang J H, Li R X, Zhu W 2014 Chin. Phys. B 23 100307

    [4]

    Chen W F, Wei Z J, Guo L, Hou L Y, Wang G, Wang J D, Zhang Z M, Guo J P, Liu S H 2014 Chin. Phys. B 23 080304

    [5]

    Zhou Y Y, Zhou X J, Tian P G, Wang Y J 2013 Chin. Phys. B 22 010305

    [6]

    Zhou R R, Y L 2012 Chin. Phys. B 21 080301

    [7]

    Lo H K, Chau H F 1999 Science 283 2050

    [8]

    Shor P W, Preskill J 2000 Phys. Rev. Lett. 85 441

    [9]

    Mayers D 2001 J. ACM 48 351

    [10]

    Makarov V, Anisimov A, Skaar J 2006 Phys. Rev. A 74 022313

    [11]

    Zhao Y, Fung C H F, Qi B, Chen C, Lo H K 2008 Phys. Rev. A 78 042333

    [12]

    Fung C H F, Qi B, Tamaki K, Lo H K 2007 Phys. Rev. A 75 032314

    [13]

    Jain N, Wittmann C, Lydersen L, Wiechers C, Elser D, Marquardt C, Makarov V, Leuchs G 2011 Phys. Rev. Lett. 107 110501

    [14]

    Acín A, Brunner N, Gisin N, Massar S, Pironio S, Scarani V 2007 Phys. Rev. Lett. 98 230501

    [15]

    Gisin N, Pironio S, Sangouard N 2010 Phys. Rev. Lett. 105 070501

    [16]

    Lo H K, Curty M, Qi B 2012 Phys. Rev. Lett. 108 130503

    [17]

    Ma X, Razavi M 2012 Phys. Rev. A 86 062319

    [18]

    Tang Y L, Yin H L, Chen S J, Liu Y, Zhang W J, Jiang X, Zhang L, Wang J, You L X, Guan J Y, Yang D X, Wang Z, Liang H, Zhang Z, Zhou N, Ma X, Chen T Y, Zhang Q, Pan J W 2015 IEEE J. Select. Topics Quantum Electron. 21 6600407

    [19]

    Zhou C, Bao W S, Chen W, Li H W, Yin Z Q, Wang Y, Han Z F 2013 Phys. Rev. A 88 052333

    [20]

    Wang Y, Bao W S, Li H W, Zhou C, Li Y 2014 Chin. Phys. B 23 080303

    [21]

    Dong C, Zhao S H, Zhao W H, Shi L, Zhao G H 2014 Acta Phys. Sin. 63 030302 (in Chinese) [东晨, 赵尚弘, 赵卫虎, 石磊, 赵顾灏 2014 物理学报 63 030302]

    [22]

    Liu Y, Chen T Y, Wang L J, Liang H, Shentu G L, Wang J, Cui K, Yin H L, Liu N L, Li L, Ma X, Pelc J S, Fejer M M, Peng C Z, Zhang Q, Pan J W 2013 Phys. Rev. Lett. 111 130502

    [23]

    da Silva T F, Vitoreti D, Xavier G B, do Amaral G C, Tempor o G P, von der Weid J P 2013 Phys. Rev. A 88 052303

    [24]

    Wang Q, Wang X B 2013 Phys. Rev. A 88 052332

    [25]

    Dong C, Zhao S H, Zhang N, Dong Y, Zhao W H, Liu Y 2014 Acta Phys. Sin. 63 200304 (in Chinese) [东晨, 赵尚弘, 张宁, 董毅, 赵卫虎, 刘韵 2014 物理学报 63 200304]

    [26]

    Li M, Zhang C M, Yin Z Q, Chen W, Wang S, Guo G C, Han Z F 2014 Opt. Lett. 39 880

    [27]

    Ma X, Fung C H F, Razavi M 2012 Phys. Rev. A 86 052305

  • [1]

    Gisin N, Ribordy G, Tittel W, Zbinden H 2002 Rev. Mod. Phys. 74 145

    [2]

    Li M, Patcharapong T, Zhang C M, Yin Z Q, Chen W, Han Z F 2015 Chin. Phys. B 24 010302

    [3]

    Ma H Q, Wei K J, Yang J H, Li R X, Zhu W 2014 Chin. Phys. B 23 100307

    [4]

    Chen W F, Wei Z J, Guo L, Hou L Y, Wang G, Wang J D, Zhang Z M, Guo J P, Liu S H 2014 Chin. Phys. B 23 080304

    [5]

    Zhou Y Y, Zhou X J, Tian P G, Wang Y J 2013 Chin. Phys. B 22 010305

    [6]

    Zhou R R, Y L 2012 Chin. Phys. B 21 080301

    [7]

    Lo H K, Chau H F 1999 Science 283 2050

    [8]

    Shor P W, Preskill J 2000 Phys. Rev. Lett. 85 441

    [9]

    Mayers D 2001 J. ACM 48 351

    [10]

    Makarov V, Anisimov A, Skaar J 2006 Phys. Rev. A 74 022313

    [11]

    Zhao Y, Fung C H F, Qi B, Chen C, Lo H K 2008 Phys. Rev. A 78 042333

    [12]

    Fung C H F, Qi B, Tamaki K, Lo H K 2007 Phys. Rev. A 75 032314

    [13]

    Jain N, Wittmann C, Lydersen L, Wiechers C, Elser D, Marquardt C, Makarov V, Leuchs G 2011 Phys. Rev. Lett. 107 110501

    [14]

    Acín A, Brunner N, Gisin N, Massar S, Pironio S, Scarani V 2007 Phys. Rev. Lett. 98 230501

    [15]

    Gisin N, Pironio S, Sangouard N 2010 Phys. Rev. Lett. 105 070501

    [16]

    Lo H K, Curty M, Qi B 2012 Phys. Rev. Lett. 108 130503

    [17]

    Ma X, Razavi M 2012 Phys. Rev. A 86 062319

    [18]

    Tang Y L, Yin H L, Chen S J, Liu Y, Zhang W J, Jiang X, Zhang L, Wang J, You L X, Guan J Y, Yang D X, Wang Z, Liang H, Zhang Z, Zhou N, Ma X, Chen T Y, Zhang Q, Pan J W 2015 IEEE J. Select. Topics Quantum Electron. 21 6600407

    [19]

    Zhou C, Bao W S, Chen W, Li H W, Yin Z Q, Wang Y, Han Z F 2013 Phys. Rev. A 88 052333

    [20]

    Wang Y, Bao W S, Li H W, Zhou C, Li Y 2014 Chin. Phys. B 23 080303

    [21]

    Dong C, Zhao S H, Zhao W H, Shi L, Zhao G H 2014 Acta Phys. Sin. 63 030302 (in Chinese) [东晨, 赵尚弘, 赵卫虎, 石磊, 赵顾灏 2014 物理学报 63 030302]

    [22]

    Liu Y, Chen T Y, Wang L J, Liang H, Shentu G L, Wang J, Cui K, Yin H L, Liu N L, Li L, Ma X, Pelc J S, Fejer M M, Peng C Z, Zhang Q, Pan J W 2013 Phys. Rev. Lett. 111 130502

    [23]

    da Silva T F, Vitoreti D, Xavier G B, do Amaral G C, Tempor o G P, von der Weid J P 2013 Phys. Rev. A 88 052303

    [24]

    Wang Q, Wang X B 2013 Phys. Rev. A 88 052332

    [25]

    Dong C, Zhao S H, Zhang N, Dong Y, Zhao W H, Liu Y 2014 Acta Phys. Sin. 63 200304 (in Chinese) [东晨, 赵尚弘, 张宁, 董毅, 赵卫虎, 刘韵 2014 物理学报 63 200304]

    [26]

    Li M, Zhang C M, Yin Z Q, Chen W, Wang S, Guo G C, Han Z F 2014 Opt. Lett. 39 880

    [27]

    Ma X, Fung C H F, Razavi M 2012 Phys. Rev. A 86 052305

  • [1] Zhou Jiang-Ping, Zhou Yuan-Yuan, Zhou Xue-Jun. Asymmetric channel phase matching quantum key distribution. Acta Physica Sinica, 2023, 72(14): 140302. doi: 10.7498/aps.72.20230652
    [2] Zhou Jiang-Ping, Zhou Yuan-Yuan, Zhou Xue-Jun. Improved parameter optimization method for measurement device independent protocol. Acta Physica Sinica, 2023, 72(12): 120303. doi: 10.7498/aps.72.20230179
    [3] Zhou Yang, Ma Xiao, Zhou Xing-Yu, Zhang Chun-Hui, Wang Qin. Study of practical state-preparation error tolerant reference-frame-independent quantum key distribution protocol. Acta Physica Sinica, 2023, 72(24): 240301. doi: 10.7498/aps.72.20231144
    [4] Liu Tian-Le, Xu Xiao, Fu Bo-Wei, Xu Jia-Xin, Liu Jing-Yang, Zhou Xing-Yu, Wang Qin. Regression-decision-tree based parameter optimization of measurement-device-independent quantum key distribution. Acta Physica Sinica, 2023, 72(11): 110304. doi: 10.7498/aps.72.20230160
    [5] Meng Jie, Xu Le-Chen, Zhang Cheng-Jun, Zhang Chun-Hui, Wang Qin. Overview of applications of heralded single photon source in quantum key distribution. Acta Physica Sinica, 2022, 71(17): 170304. doi: 10.7498/aps.71.20220344
    [6] Du Cong, Wang Jin-Dong, Qin Xiao-Juan, Wei Zheng-Jun, Yu Ya-Fei, Zhang Zhi-Ming. A simple protocol for measuring device independent quantum key distribution based on hybrid encoding. Acta Physica Sinica, 2020, 69(19): 190301. doi: 10.7498/aps.69.20200162
    [7] He Feng-Tao, Du Ying, Zhang Jian-Lei, Fang Wei, Li Bi-Li, Zhu Yun-Zhou. Bit error rate of pulse position modulation wireless optical communication in gamma-gamma oceanic anisotropic turbulence. Acta Physica Sinica, 2019, 68(16): 164206. doi: 10.7498/aps.68.20190452
    [8] Gu Wen-Yuan, Zhao Shang-Hong, Dong Chen, Wang Xing-Yu, Yang Ding. Reference-frame-independent measurement-device-independent quantum key distribution under reference frame fluctuation. Acta Physica Sinica, 2019, 68(24): 240301. doi: 10.7498/aps.68.20191364
    [9] Yan Xia-Chao, Zhu Jiang, Zhang La-Bao, Xing Qiang-Lin, Chen Ya-Jun, Zhu Hong-Quan, Li Jian-Ting, Kang Lin, Chen Jian, Wu Pei-Heng. Model of bit error rate for laser communication based on superconducting nanowire single photon detector. Acta Physica Sinica, 2017, 66(19): 198501. doi: 10.7498/aps.66.198501
    [10] Sun Wei, Yin Hua-Lei, Sun Xiang-Xiang, Chen Teng-Yun. Nonorthogonal decoy-state quantum key distribution based on coherent-state superpositions. Acta Physica Sinica, 2016, 65(8): 080301. doi: 10.7498/aps.65.080301
    [11] Wu Cheng-Feng, Du Ya-Nan, Wang Jin-Dong, Wei Zheng-Jun, Qin Xiao-Juan, Zhao Feng, Zhang Zhi-Ming. Analysis on performance optimization in measurement-device-independent quantum key distribution using weak coherent states. Acta Physica Sinica, 2016, 65(10): 100302. doi: 10.7498/aps.65.100302
    [12] Wang Lü-Qiang, Su Tong, Zhao Bao-Sheng, Sheng Li-Zhi, Liu Yong-An, Liu Duo. Bit error rate analysis of X-ray communication system. Acta Physica Sinica, 2015, 64(12): 120701. doi: 10.7498/aps.64.120701
    [13] Zhou Fei, Yong Hai-Lin, Li Dong-Dong, Yin Juan, Ren Ji-Gang, Peng Cheng-Zhi. Study on quantum key distribution between different media. Acta Physica Sinica, 2014, 63(14): 140303. doi: 10.7498/aps.63.140303
    [14] Wei Zheng-Jun, Wan Wei, Wang Jin-Dong, Liao Chang-Jun, Liu Song-Hao. A new method to acquire the half-wave voltage by the quantum bit error rate in the deterministic quantum key distribution system. Acta Physica Sinica, 2011, 60(9): 094216. doi: 10.7498/aps.60.094216.1
    [15] Wang Jin-Dong, Wei Zheng-Jun, Zhang Hui, Zhang Hua-Ni, Chen Shuai, Qin Xiao-Juan, Guo Jian-Ping, Liao Chang-Jun, Liu Song-Hao. The influence of the time delay through long trunk fiber on the phase-coding quantum key distribution system. Acta Physica Sinica, 2010, 59(8): 5514-5522. doi: 10.7498/aps.59.5514
    [16] Zhang Jing, Wang Fa-Qiang, Zhao Feng, Lu Yi-Qun, Liu Song-Hao. Quantum key distribution based on time coding and phase coding. Acta Physica Sinica, 2008, 57(8): 4941-4946. doi: 10.7498/aps.57.4941
    [17] Hu Hua-Peng, Zhang Jing, Wang Jin-Dong, Huang Yu-Xian, Lu Yi-Qun, Liu Song-Hao, Lu Wei. Experimental quantum key distribution with double protocol. Acta Physica Sinica, 2008, 57(9): 5605-5611. doi: 10.7498/aps.57.5605
    [18] Chen Xia, Wang Fa-Qiang, Lu Yi-Qun, Zhao Feng, Li Ming-Ming, Mi Jing-Long, Liang Rui-Sheng, Liu Song-Hao. A phase modulated QKD system with two quantum cryptography protocols. Acta Physica Sinica, 2007, 56(11): 6434-6440. doi: 10.7498/aps.56.6434
    [19] Feng Fa-Yong, Zhang Qiang. Quantum key distribution based on hyperentanglement swapping. Acta Physica Sinica, 2007, 56(4): 1924-1927. doi: 10.7498/aps.56.1924
    [20] Chen Jie, Li Yao, Wu Guang, Zeng He-Ping. Stable quantum key distribution with polarization control. Acta Physica Sinica, 2007, 56(9): 5243-5247. doi: 10.7498/aps.56.5243
Metrics
  • Abstract views:  6619
  • PDF Downloads:  437
  • Cited By: 0
Publishing process
  • Received Date:  21 October 2014
  • Accepted Date:  02 January 2015
  • Published Online:  05 June 2015

/