A large plasma sheet with a size of 60 cm60 cm2 cm is generated in an apparatus with a hollow cathode. The electron density distribution of the large area plasma sheet is measured. Since the duration of high voltage pulse is short, we change measurement methods. Besides, modification is used for electron saturation current to get the real density. The two-dimensional electron density and electrical field distribution are calculated at discharge currents ranging from 1 to 6 A. Meanwhile we discuss other parameters related to density distribution. The electron density distribution is important for plasma sheet to steer microwave. It is encouraging that the large area plasma sheet generated by the hollow cathode is uniform and has sufficient electron density to reflect X-band (812 GHz) microwaves.
-
Keywords:
- plasma density distribution /
- plasma sheet /
- Langmuir probe array
[1] Manheimer W M 1991 IEEE Trans. Plasma Sci. 19 1228
[2] Mathew J, Meger R A, Gregor J A, Pechacek R E, Fernsler R F, Manheimer W M 1999 International Radar Conference New Jersey, USA, May 8--11, 1995 p742
[3] Mathew J, Fernsler R F, Meger R A, Gregor J A, Murphy D P, Pechacek R E, Manheimer W M 1996 Phys. Rev. Lett. 77 1982
[4] Meger R A, Mathew J, Gregor J A, Pechacek R E, Fernsler R F, Manheimer W M, Robson A E 1995 Phys. Plasmas 2 2532
[5] Robson A E, Morgan R L, Meger R A 1992 IEEE Trans. Plasma Sci. 20 1036
[6] Gregor J A, Fernsler R F, Meger R A 2003 IEEE Trans. Plasma Sci. 31 1305
[7] Murphy D P, Fernsler R F, Pechacek R E, Meger R A 2002 IEEE Trans. Plasma Sci. 30 436
[8] Huddlestone R H, Leonard S L 1965 Plasma Diagnostic Techniques (New York: Academic Press) p168
[9] Hutchinson I H 2002 Principles of Plasma Diagnostic (2nd Ed.) (Cambridge: Cambridge University Press) p81
[10] Wu Z Y, Yang Y T, Wang J Y 2010 Acta Phys. Sin. 59 1890 (in Chinese) [吴振宇, 杨银堂, 汪家友 2010 物理学报 59 1890]
[11] Wan J, Jia X H, Yang J H, Wang S G 2010 IEEE Trans. Plasma Sci. 38 2006
-
[1] Manheimer W M 1991 IEEE Trans. Plasma Sci. 19 1228
[2] Mathew J, Meger R A, Gregor J A, Pechacek R E, Fernsler R F, Manheimer W M 1999 International Radar Conference New Jersey, USA, May 8--11, 1995 p742
[3] Mathew J, Fernsler R F, Meger R A, Gregor J A, Murphy D P, Pechacek R E, Manheimer W M 1996 Phys. Rev. Lett. 77 1982
[4] Meger R A, Mathew J, Gregor J A, Pechacek R E, Fernsler R F, Manheimer W M, Robson A E 1995 Phys. Plasmas 2 2532
[5] Robson A E, Morgan R L, Meger R A 1992 IEEE Trans. Plasma Sci. 20 1036
[6] Gregor J A, Fernsler R F, Meger R A 2003 IEEE Trans. Plasma Sci. 31 1305
[7] Murphy D P, Fernsler R F, Pechacek R E, Meger R A 2002 IEEE Trans. Plasma Sci. 30 436
[8] Huddlestone R H, Leonard S L 1965 Plasma Diagnostic Techniques (New York: Academic Press) p168
[9] Hutchinson I H 2002 Principles of Plasma Diagnostic (2nd Ed.) (Cambridge: Cambridge University Press) p81
[10] Wu Z Y, Yang Y T, Wang J Y 2010 Acta Phys. Sin. 59 1890 (in Chinese) [吴振宇, 杨银堂, 汪家友 2010 物理学报 59 1890]
[11] Wan J, Jia X H, Yang J H, Wang S G 2010 IEEE Trans. Plasma Sci. 38 2006
Catalog
Metrics
- Abstract views: 7693
- PDF Downloads: 8719
- Cited By: 0