Plastic fiber image bundle with 250 single fiber diameter, 4096 pixels, 15 m length is fabricated. The result indicates that 25% of the input image remains after it has translated though the 15m fiber bundle, which can meet the need of eye observation or CCD image capture. Based on the key component of image bundle, the eye observation life detection instrument prototype and intelligent life detection instrument prototype connected with CCD, image capture card and portable computer are designed and produced. The effectiveness of researching and rescuing the person from danger is demonstrated. The system can be used not only for researching and rescuing the buried person, but also for video monitoring some special occasions, such as strong electromagnetic interference environment, security department and explosive places.
-
Keywords:
- plastic fiber /
- image bundle /
- fiber endoscope /
- post-earthquake research and rescue
[1] Peng J C, CHEN W F, XIE D L, GUO Y, CAO X Y, QIN J 2007 Earthquake Research in Sichuan 124 13 (in Chinese) [彭晋川, 陈维锋, 谢德林, 郭勇, 曹型勇, 秦军 2007 四川地震 124 13]
[2] Fang F, Lin M R, Li Y J, Zhang B Z 2000 Acta Opt. Sin. 20 654 (in Chinese) [房芳, 林美荣, 李英杰, 张包铮 2000 光学学报 20 654]
[3] Liu D S, Yin Z M, Zhu S L 1987 Fiber Optics (Beijing: Science Press) p54 (in Chinese) [刘德森, 殷宗敏, 祝颂来 1987 纤维光学 (北京: 科学出版社) 第54页]
[4] Wang H, Xiang Y, Yu B X 2005 Opt. Precision Eng. 13 185 (in Chinese) [王慧, 向阳, 禹秉熙 2005 光学精密工程 13 185]
[5] Zhou D C, Yu F X, Tan F 2009 Chin. J. Lasers 36 723 (in Chinese) [周德春, 于凤霞, 谭芳 2009 中国激光 36 723]
[6] Zhang W S, Zhao W, Dou Z Z 2004 Chinese Patent 200410073591.1 (in Chinese) [张文松, 赵卫, 窦治中 2004 中国发明专利 200410073591.1]
[7] Kong D P, Wang L L 2009 Opt. Lett. 34 2435 Guo Z L, Wang L L 2009 Acta Photonica Sin. 38 3176 (in Chinese) [郭昭龙, 王丽莉 2009 光子学报 38 3176]
[8] Kong D P, Wang L L 2009 Acta Photonica Sin. 38 2913 (in Chinese) [孔德鹏, 王丽莉 2009 光子学报 38 2913]
[9] Jiang Y, Zou N Y 2002 Polymer fiber (Beijing: Chemical Industry Press) P271 (in Chinese) [江源, 邹宁宇 2002 聚合物光纤 (北京: 化学工业出版社) 第271页]
-
[1] Peng J C, CHEN W F, XIE D L, GUO Y, CAO X Y, QIN J 2007 Earthquake Research in Sichuan 124 13 (in Chinese) [彭晋川, 陈维锋, 谢德林, 郭勇, 曹型勇, 秦军 2007 四川地震 124 13]
[2] Fang F, Lin M R, Li Y J, Zhang B Z 2000 Acta Opt. Sin. 20 654 (in Chinese) [房芳, 林美荣, 李英杰, 张包铮 2000 光学学报 20 654]
[3] Liu D S, Yin Z M, Zhu S L 1987 Fiber Optics (Beijing: Science Press) p54 (in Chinese) [刘德森, 殷宗敏, 祝颂来 1987 纤维光学 (北京: 科学出版社) 第54页]
[4] Wang H, Xiang Y, Yu B X 2005 Opt. Precision Eng. 13 185 (in Chinese) [王慧, 向阳, 禹秉熙 2005 光学精密工程 13 185]
[5] Zhou D C, Yu F X, Tan F 2009 Chin. J. Lasers 36 723 (in Chinese) [周德春, 于凤霞, 谭芳 2009 中国激光 36 723]
[6] Zhang W S, Zhao W, Dou Z Z 2004 Chinese Patent 200410073591.1 (in Chinese) [张文松, 赵卫, 窦治中 2004 中国发明专利 200410073591.1]
[7] Kong D P, Wang L L 2009 Opt. Lett. 34 2435 Guo Z L, Wang L L 2009 Acta Photonica Sin. 38 3176 (in Chinese) [郭昭龙, 王丽莉 2009 光子学报 38 3176]
[8] Kong D P, Wang L L 2009 Acta Photonica Sin. 38 2913 (in Chinese) [孔德鹏, 王丽莉 2009 光子学报 38 2913]
[9] Jiang Y, Zou N Y 2002 Polymer fiber (Beijing: Chemical Industry Press) P271 (in Chinese) [江源, 邹宁宇 2002 聚合物光纤 (北京: 化学工业出版社) 第271页]
Catalog
Metrics
- Abstract views: 6426
- PDF Downloads: 692
- Cited By: 0