强流脉冲离子束辐照后的材料表面状态对束流强度具有极高的敏感性. 因此, 在辐照实验中监测束流输出的稳定性, 并及时识别出参数抖动较大的脉冲, 对于实验结果的分析和表面改性效果的优化具有重要意义. 本文利用塑料闪烁体构建了一种时间分辨为6 ns的快响应脉冲X射线诊断系统, 成功捕获了外磁绝缘离子束二极管工作时产生的X射线. 同时, 通过红外相机和法拉第筒对离子束流的能量密度和电流密度进行测量. 分析结果显示, 轫致辐射强度和离子束发射强度均取决于二极管加速电压, 导致X射线强度和离子束流能量密度呈现正相关趋势. 当离子电流密度发生抖动时, X射线信号幅值表现出良好的变化跟随性, 能够对偏离预设参数区间的脉冲做出响应. 这说明本文提出的非拦截式诊断方法能够有效地实时监测强流脉冲离子束束流输出的稳定性.Intense pulsed ion beam (IPIB) technology has made remarkable progress in surface modification, mixing, polishing, film deposition, and nano powder synthesis in recent years. However, the surface properties of materials under IPIB irradiation are highly sensitive to beam intensity variations. Deviations from acceptable parameter range can change the surface characteristics and increase prevalence of defects. Consequently, the real-time online monitoring of beam stability during irradiation experiments and promptly identifying of pulses exhibiting significant parameter jitter are of significance in accurately analyzing results and optimizing surface modification. This study presents a fast-response pulse X-ray diagnostic system by employing EJ-200 plastic scintillator, 9266FLB photomultiplier tube, and Tektronic TDS 2024 four-channel oscilloscope. Single particle test demonstrates that the system achieves a time resolution of 6 ns, meeting the requirements for temporal response to detecting pulse X-ray signals with a half-width of ~80 ns. By adjusting the insulation magnetic field strength of the ion diode, the IPIB output level is regulated. The diagnostic system successfully captures X-rays emitted by the external magnetic insulated ion diode operating at different output levels. Simultaneously, the ion beam energy density is measured by using an infrared camera. To mitigate diagnostic errors stemming from target ablation, the maximum energy density is controlled to be below 1.32 J/cm2. Analysis results establish a positive correlation between X-ray intensity and ion beam energy density. This relationship arises from the influence of the insulating magnetic field adjustment on the diode's operating voltage, which subsequently affects the bremsstrahlung radiant intensity and ion beam emission intensity. This correlation offers the potential for the real-time monitoring of IPIB beam output stability by utilizing X-ray signals. To further corroborate the synchronized changes in pulse X-ray intensity and ion beam intensity, Faraday cup is employed as an alternative to infrared imaging method for measuring ion current density. Results demonstrate that the amplitude of the X-ray signal changes synchronously with fluctuations of ion current density. It is worth noting that when the output intensity of ion beam deviates significantly (more than 10% of the preset value), the diagnostic system will respond quickly. These findings validate the efficacy of the proposed non-interceptive diagnostic method of real-time monitoring the intense pulsed ion beam output stability.
1. 引 言
强流脉冲离子束(intense pulsed ion beam, IPIB)技术的起源可以追溯到20世纪60年代对惯性约束核聚变(inertial confinement fusion, ICF)点火技术的研究[1-3]. 许多研究中也将IPIB用于准单能γ射线的产生以及模拟材料的软X射线热-力学效应[4-6]. 尽管早期的IPIB技术主要聚焦军工行业, 但随着时代的发展, 近年来, IPIB的应用逐渐扩展到民用领域, 尤其是在材料表面工程领域取得了显著的成就.
应用于材料科学的IPIB不再追求极高的离子能量和束流强度, 其典型参数如下[7,8]: 离子能量100—500 keV, 离子电流密度几十至几百A/cm2, 脉冲宽度几十至几百ns. 此特征参数的IPIB可以在短时间内将几至几十J/cm2的能量沉积在材料浅表层(深度为μm量级), 产生极高的体功率密度, 可使材料表层在几百至几千ns内升温至数千摄氏度并迅速冷却至室温, 加热和冷却的速率高达109—1010 K/s[9,10]. 基于以上特点, IPIB技术在表面改性[11-13]、表面混熔[14,15]、表面抛光[16,17]、薄膜沉积[18,19]、纳米粉末合成[20]等领域得到广泛应用.
在利用IPIB进行材料表面辐照的过程中, 由于气体开关存在击穿抖动和阳极表面状态变化等因素的影响, 不同脉冲之间输出的束流强度有时会出现一定程度的波动. 此外, 材料在IPIB辐照后的表面状态对于束流强度非常敏感[21-25], 偏离设定参数范围的束流辐照会影响表面形貌和缺陷密度. 如果某个脉冲的IPIB束流强度明显偏离预期, 这将对表面改性的整体效果产生影响, 特别是在低脉冲个数的辐照条件下, 这种影响更加显著. 因此, 在材料辐照过程中实现对IPIB束流强度的在线监测, 及时甄别异常强度的脉冲, 对于有效分析评估实验结果、优化改进辐照参数以及提升表面改性效果具有十分重要的意义.
目前存在几种较为成熟的IPIB束流诊断方法, 包括法拉第筒用于测量离子电流密度[26]、量热器或红外相机用于测量束流能通量[27,28]等. 这些方法可以直接用于诊断IPIB的束流强度, 但都属于束流截断式测量方法, 无法与IPIB材料辐照实验同步进行. 近年来, 还发展出了一些间接诊断IPIB束流强度的方法, 如核反应法和应力波测量法, 为在线监测IPIB的束流稳定性提供了可能, 但这些方法也存在使用场景限制. 核反应法即利用IPIB轰击特定靶材(如BN, B4C)诱发核反应, 通过测量瞬发γ射线或反应产物衰变时放出的γ射线来间接推定IPIB的束流参数[29,30]. 然而, 该方法要求入射离子的能量达到诱发核反应的临界值, 并且对靶材成分有严格要求, 无法满足靶材多样化和低能IPIB诊断的实际需求. 另一种方法是利用压电转换器测量IPIB辐照靶材引发的应力波来间接监测IPIB束流强度的抖动[31,32]. 然而, 该方法要求靶材与压电转换器之间实现良好的耦合, 且对于刚度较小的靶材适用性还不确定.
因此, 为了发展高效且应用广泛的IPIB束流稳定性在线监测系统, 必须采用非拦截式的测量方式, 且摆脱对靶材的依赖性. 一种切实可行的方案是获取和分析IPIB形成或输运过程中产生的并发辐射信息, 例如离子束二极管工作过程中产生的轫致辐射或等离子体光谱. 之前的实验研究中, Masugata等[33]和杨海亮等[34]在实验中曾发现磁绝缘离子束二极管中阴极出射的电子轰击阳极及其周边结构会导致脉冲轫致辐射的产生. 然而, 迄今为止, 对于该并发产生的脉冲轫致辐射的深入分析研究还相对较少.
本文设计了一种基于EJ-200塑料闪烁体的快速响应脉冲X射线探测系统, 用于捕获外磁绝缘离子束二极管发射IPIB时产生的脉冲轫致辐射信号. 通过将该捕获的信号与IPIB束流能量密度和电流密度进行对比分析, 发现脉冲X射线信号的强度与IPIB束流强度之间存在显著的正相关性和变化一致性. 这一结果表明, 外磁绝缘离子束二极管产生的X射线可以有效用于在线监测IPIB束流输出的稳定性.
2. 诊断系统与方法
本次实验在北京航空航天大学高能量密度物理实验室的强流脉冲离子束加速器(BIPPAB-450)上进行. 该装置的前端是磁脉冲发生器, 能够产生高达250 kV的高压脉冲. Blumlein脉冲成形线的介质是去离子水, 可以将高压脉冲整形并压缩至80 ns (FWHM). 经过压缩的脉冲经过自耦变压器升压至450 kV, 然后加载到磁绝缘离子束二极管上. 该二极管的内、外阴极结构中各嵌有一个同轴线圈, 在线圈上施加脉冲电流可以在阴-阳极间隙产生横向磁场, 用于限制阴极出射电子的运动, 以提高离子束的产生效率. 由于磁场线圈通电后在真空环境中存在散热过程, 因此BIPPAB-450在离子束发射模式下的工作频率不超过1/60, 即每分钟发射一次脉冲. 该装置工作原理的详细描述见文献[35]. 用于获取脉冲X射线信号的探测系统和方法如图1所示. 由于BIPPAB-450产生的IPIB具有短脉冲宽度, 半高宽仅为80 ns, 因此在本实验中选择了具有快时间响应的EJ-200塑料闪烁体作为射线探测晶体, 其尺寸为13 cm×3.5 cm×0.5 cm. 此外, 塑料闪烁体具有耐辐照特性, 可以确保探测系统在强辐射环境下的稳定性. 塑料闪烁体后端耦合了9266FLB光电倍增管, 用于实现光电信号转换与放大. 光电倍增管输出的信号通过同轴电缆传输到Tektronic TDS 2024四通道示波器进行记录. 探测器位于真空靶室的侧面, 距离离子束二极管中心位置直线距离1 m. 为了验证轫致辐射信号与IPIB束流强度之间的关联性, 还同步采用红外成像方法对IPIB的束流能量密度进行诊断. 热沉靶材选用304不锈钢, 放置在距二极管阴极出口15 cm处的束斑焦点位置, 其尺寸为10 cm×10 cm, 厚度为100 μm. 红外相机的型号为Fluke Ti25, 采用远程控制机械臂触发的方式, 以降低IPIB参数获取的时间延迟. 有关红外诊断方法的详细介绍可参考文献[36].
3. 实验结果与讨论
3.1 诊断系统的响应时间
为了准确获得脉冲X射线的时间特性, 诊断系统的响应时间需满足一定要求, 以避免脉冲辐射信号由于波形展宽而出现失真. 通常要求诊断系统的时间响应半高宽不超过被测辐射脉冲半高宽的1/3[37]. 本研究采用单粒子法(宇宙线粒子)[38]对系统的时间响应特性进行测量, 结果如图2所示. 所搭建的诊断系统响应时间半高宽为6 ns, 远小于BIPPAB-450输出脉冲的80 ns半高宽, 因此能够满足测试要求.
3.2 脉冲X射线强度与IPIB束流强度的关联性
为验证脉冲X射线与IPIB束流之间的关联性, 选择10个不同的IPIB束流能量密度, 并将与测得的X射线信号强度进行比对. 束流强度的调节是通过改变离子束二极管的绝缘磁场强度实现的. 绝缘磁场决定了二极管阻抗, 进而影响二极管的工作电压. 在BIPPAB-450装置中, 当绝缘磁场的强度小于1.18 T时, 随着绝缘磁场的增大, 二极管的工作电压增大, 从而导致输出的IPIB束流强度增大[39]. 为避免靶材烧蚀对束流能量密度的诊断误差, 将束流的最高能量密度控制在1.32 J/cm2以下. 在IPIB辐照前后, 从热沉靶的背面捕获了红外图像, 具体见图3(a)和图3(b). 同时, 诊断系统同步捕获了脉冲X射线信号, 如图3(c)所示.
图4统计了不同IPIB束流能量密度下的X射线信号幅值, 可以观察到二者存在明显的正相关性. 根据理论分析, 这种现象是合理的, 因为脉冲X射线信号强度和IPIB束流强度都与二极管的工作电压(电子和离子的加速电压)密切相关. 实验中捕获的脉冲X射线的主要来自阴极出射电子轰击阳极及阳极周围结构所产生的轫致辐射, 图5(a)展示了该过程的示意图. 而图5(b)显示了除环状阳极区域外, 阳极托盘中心处也存在明显的电子辐照痕迹. 根据Fowler-Nordheim公式, 阴极场致发射电子的强度Je与电压U之间存在以下关系式:
$$ {J}_{{\rm{e}}}=A{\beta }^{2}{U}^{2}{\rm{exp}}\left(\frac{-B}{\beta U}\right),$$ (1) 其中, A和B是与发射体相关的功函数, β为场强变换几何因子. 从(1)式可以看出, 加速电压的增大会导致阴极场致发射电子数量的增加. 此外, 单个电子的轫致辐射能量损失率[40]可表示为
$$ {\left(\frac{{\rm{d}}E}{{\rm{d}}x}\right)}_{{\rm{r}}{\rm{a}}{\rm{d}}}\propto U\frac{{e}^{3}{Z}^{2}}{{{m}_{{\rm{e}}}^2}}N, $$ (2) 其中, me和e分别为电子质量和电子电荷, Z和N分别为吸收物质的原子序数和原子密度. 因此, 阴极发射的电子与阳极相互作用产生的总体轫致辐射强度可表示为
$$ {E}_{{\rm{r}}{\rm{a}}{\rm{d}}}={J}_{{\rm{e}}}\cdot Ue\cdot {\left(\frac{{\rm{d}}E}{{\rm{d}}x}\right)}_{{\rm{r}}{\rm{a}}{\rm{d}}}\propto {J}_{{\rm{e}}}{U}^{2}\frac{{e}^{4}{Z}^{2}}{{{m}_{{\rm{e}}}^2}}N. $$ (3) 不难观察到, 轫致辐射强度Erad与二极管加速电压U呈正相关.
同时, 根据Child-Langmiur定律, 离子束流强度Ji与电压U3/2成正比:
$$ {J}_{{\rm{i}}}=\frac{4K{\varepsilon }_{0}}{9}{\left(\frac{2{Z}_{{\rm{i}}}}{{m}_{{\rm{i}}}}\right)}^{\frac{1}{2}}\frac{{U}^{\frac{3}{2}}}{{d}^{2}}, $$ (4) 其中, K为由二极管的几何聚焦产生的常数,
$\varepsilon_0 $ 是真空介电常数, mi和Zi分别是离子质量和离子电荷数, d为阴阳极间距. 结合(1), (3), (4)式, 可得到以下关系:$$ {E}_{{\rm{r}}{\rm{a}}{\rm{d}}}\propto {{J}_{{\rm{i}}}}^{\frac{8}{3}}{\rm{exp}}\left(-\frac{B}{\beta }{{J}_{{\rm{i}}}}^{-\frac{2}{3}}\right), $$ (5) (5)式证明了轫致辐射强度Erad与离子束流强度Ji之间存在正相关性. 因此, 脉冲X射线信号的幅值可以与IPIB束流强度同步地变化. 这为利用X射线信号实时监测IPIB束流输出的稳定性提供了可能性.
3.3 系统的在线测试
为进一步验证IPIB束流在线监测方法的可靠性, 使用法拉第筒替代了红外成像方法, 用于测量IPIB的离子电流密度. 法拉第筒放置在距二极管阴极出口15 cm处的束斑焦点位置, 如图6所示. 同时利用诊断系统和高压分压器分别测量脉冲X射线信号和二极管电压信号, 并将3个信号输入Tektronic TDS 2024四通道示波器进行波形采集. 实验测量得到的波形图如图7所示. 离子束二极管与探测晶体的距离为1 m, X射线从源点直射入探测器所需要的时间约3 ns. 9266FLB光电倍增管的渡越时间为40 ns. 脉冲X射线信号通道的同轴电缆长度比其他通道长2.5 m, 信号在同轴电缆中传输的速度约为光速的80%, 因此脉冲X射线信号晚于其他通道信号约10 ns进入示波器. 多因素综合作用导致脉冲X射线信号滞后于二极管电压信号约55 ns. 此外, 由于X射线在空间传输过程中存在散射, 散射光子的在进入探测晶体前运动路径相对于直射光子更长, 导致了X射线信号的波形出现拖尾现象.
为了测试不同强度的IPIB在发生输出抖动时, 诊断系统能否实现同步响应, 选择3种不同的束流水平, 分别为30, 60, 110 A/cm2. 根据图8的结果可以看出, 当IPIB的束流强度明显变化时, 脉冲X射线诊断系统输出的信号强度也会同步改变. 在低束流强度区间, X射线信号显示出良好的同步跟随性. 在高束流强度区间, 当出现较大的强度抖动(超过10%), X射线信号能够灵敏地同步响应. 结果表明该诊断系统能够帮助实验人员实现对IPIB束流输出稳定性的在线监测, 及时识别出发生明显输出抖动的脉冲.
4. 结 论
本文针对辐照实验中需要实时监测IPIB束流输出稳定性的需求, 设计了一种基于塑料闪烁体的脉冲X射线诊断系统, 并利用X射线信号特征实现了IPIB束流稳定性的在线监测. 单粒子测试显示该系统的响应时间仅为6 ns, 能够对脉冲半高宽为80 ns的轫致辐射场进行探测. 同时, 采用红外成像法对IPIB束流能量密度进行测量, 发现X射线信号强度随束流能量密度增大而增大. 利用离子束流强度和轫致辐射强度对二极管加速电压的依赖关系进行定性解释, 阐明了这种趋势的产生原因. 通过使用法拉第筒进一步验证了脉冲X射线强度与IPIB束流强度变化的同步性, 发现当IPIB的束流强度发生较大偏离(超过预定值的10%)时, X射线信号的幅值表现出良好的跟随性. 研究结果表明, 本文提出的方法能够有效地识别出跳离预定参数范围的脉冲, 为在线诊断IPIB束流输出的稳定性提供了一种非拦截式的监测方法.
[1] Humphries S 1980 Nucl. Fusion 20 1549Google Scholar
[2] Van Devender J P 1986 Plasma Phys. Control. Fusion 28 841Google Scholar
[3] Long K A, Tahir N A 1982 Phys. Lett. A 91 451Google Scholar
[4] 杨海亮, 邱爱慈, 张嘉生, 何小平, 孙剑锋, 彭建昌, 汤俊萍, 任书庆, 欧阳晓平, 张国光, 黄建军, 杨莉, 王海洋, 李洪玉, 李静雅 2004 物理学报 53 406Google Scholar
Yang H L, Qiu A C, Zhang J S, He X P, Sun J F, Peng J C, Tang J P, Ren S Q, Ouyang X P, Zhang G G, Huang J J, Yang L, Wang H Y, Li H Y, Li J Y 2004 Acta Phys. Sin. 53 406Google Scholar
[5] Mach H, Rogers D W O 1983 IEEE Trans. Nucl. Sci. 30 1514Google Scholar
[6] Baumung K, Bluhm H J, Goel B, Hoppé P, Karow H U, Rusch D, Fortov V E, Kanel G I, Razorenov S V, Utkin A V, Vorobjev O Y 1996 Laser Part. Beams 14 181Google Scholar
[7] Zhong H W, Zhang J, Shen J, Liang G Y, Zhang S J, Huang W Y, Xu M F, Yu X, Yan S, Efimovich Remnev G, Le X Y 2019 Nucl. Instruments Methods Phys. Res. Sect. B Beam Interact. with Mater. Atoms 461 226Google Scholar
[8] Yu X, Zhang S J, Stepanov A V, Shamanin V I, Zhong H W, Liang G Y, Xu M F, Zhang N, Kuang S, Ren J, Shang X, Yan S, Remnev G E, Le X Y 2020 Surf. Coatings Technol. 384 125351Google Scholar
[9] 张世健, 喻晓, 钟昊玟, 梁国营, 许莫非, 张楠, 任建慧, 匡仕成, 颜莎, Gennady Efimovich Remnev, 乐小云 2020 物理学报 69 115202Google Scholar
Zhang S J, Yu X, Zhong H W, Liang G Y, Xu M F, Zhang N, Ren J H, Kuang S C, Yan S, Gennady E R, Le X Y 2020 Acta Phys. Sin. 69 115202Google Scholar
[10] Le X Y, Zhao W J, Yan S, Han B X, Xiang W 2002 Surf. Coatings Technol. 158 – 159 14
[11] 张锋刚, 朱小鹏, 王明阳, 雷明凯 2011 金属学报 47 958
Zhang F G, Zhu X P, Wang M Y, Lei M K 2011 Acta Metall. Sin. 47 958
[12] Zhang S J, Yu X, Zhang J, Shen J, Zhong H W, Liang G Y, Xu M, Zhang N, Ren J, Kuang S, Shang X, Adegboyega O, Yan S, Remnev G E, Le X Y 2021 Vacuum 187 110154Google Scholar
[13] Zhao W J, Remnev G E, Yan S, Opekounov M S, Le X Y, Matvienko V M, Han B X, Xue J M, Wang Y G 2000 Rev. Sci. Instrum. 71 1045Google Scholar
[14] Yan S, Le X Y, Zhao W J, Shang Y J, Wang Y, Xue J 2007 Surf. Coatings Technol. 201 4817Google Scholar
[15] Xu M F, Yu X, Zhang S J, Yan S, Tarbokov V, Remnev G, Le X Y 2023 Materials (Basel) 16 3028
[16] Yu X, Shen J, Zhong H W, Zhang J, Yan S, Zhang G L, Zhang X, Le X Y 2015 Vacuum 120 116Google Scholar
[17] Hashimoto Y, Yatsuzuka M 2000 Vacuum 59 313Google Scholar
[18] Prasad S V, Renk T J, Kotula P G, DebRoy T 2011 Mater. Lett. 65 4Google Scholar
[19] Suzuki T, Saikusa T, Suematu H, Jiang W, Yatsui K 2003 Surf. Coatings Technol. 169 – 170 491
[20] Zhu Q, Jiang W, Yatsui K 1999 J. Appl. Phys. 86 5279Google Scholar
[21] Shulov V A, Novikov A S, Paikin A G, Belov A B, Lvov A F, Remnev G E 2007 Surf. Coatings Technol. 201 8654Google Scholar
[22] Zhang J, Zhong H W, Shen J, Yu X, Yan S, Le X Y 2020 Surf. Coatings Technol. 388 125599Google Scholar
[23] Kovivchak V S, Panova T V, Mikhailov K A, Knyazev E V 2013 J. Surf. Investig. 7 531Google Scholar
[24] Zhang Q, Mei X X, Guan T, Zhang X N, Remnev G E, Pavlov S K, Wang Y N 2019 Fusion Eng. Des. 138 16Google Scholar
[25] Mei X X, Zhang X N, Liu X, Wang Y N 2017 Nucl. Instruments Methods Phys. Res. Sect. B Beam Interact. with Mater. Atoms 406 697Google Scholar
[26] Gerdin G, Stygar W, Venneri F 1981 J. Appl. Phys. 52 3269Google Scholar
[27] Christodoulides C E, Freeman J H 1976 Nucl. Instruments Methods 135 13Google Scholar
[28] Davis H A, Bartsch R R, Olson J C, Rej D J, Waganaar W J 1997 J. Appl. Phys. 82 3223Google Scholar
[29] Ryzhkov V A, Stepanov A V, Pyatkov I N, Remnev G E 2021 Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 1013 165671Google Scholar
[30] Ryzhkov V A, Pyatkov I N, Remnev G E 2021 Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 998 165190Google Scholar
[31] Pushkarev A I, Isakova Y I, Yu X, Khailov I P 2013 Rev. Sci. Instrum. 84
[32] Dong Z H, Liu C, Han X G, Lei M K 2007 Surf. Coatings Technol. 201 5054Google Scholar
[33] Masugata K, Chishiro E, Yatsui K 1998 Proceedings of the 12th International Conference on High-Power Particle Beams Haifa, Israel, June 12, 1998 pp222–225
[34] 杨海亮, 邱爱慈, 孙剑锋, 何小平, 汤俊萍, 王海洋, 李洪玉, 李静雅, 任书庆, 黄建军, 张嘉生, 彭建昌, 欧阳晓平, 张国光 2004 原子能科学技术 38 204
Yang H L, Qiu A C, Sun J F, He X P, Tang J P, Wang H Y, Li H Y, Li J Y, Ren S Q, Huang J J, Zhang J S, Peng J C, Ouyang X P, Zhang G G 2004 Atom. Ener. Sci. Tech. 38 204
[35] Yu X, Shen J, Isakova Y I, Zhong H W, Zhang J, Yan S, Zhang G L, Zhang X F, Le X Y 2015 Vacuum 122 12Google Scholar
[36] 屈苗, 喻晓, 张洁, 沈杰, 钟昊玟, 张艳燕, 颜莎, 张小富, 张高龙, 乐小云 2015 强激光与粒子束 27 216Google Scholar
Qu M, Yu X, Zhang J, Shen J, Zhong H W, Zhang Y Y, Yan S, Zhang X F, Zhang G L, Le X Y 2015 High Power Laser and Particle Beams 27 7Google Scholar
[37] 刘庆兆 1994 脉冲辐射场诊断技术 (北京: 科学出版社) 第98页
Liu Q Z 1994 Pulse Radiation Field Diagnosis Technology (Beijing: Science Press) p98
[38] 郑志鹏, 祝玉灿, 邵毓莺, 孙汉生 1986 核电子学与探测技术 6 112
Zheng Z P, Zhu Y C, Shao Y Y, Sun H S 1986 Nucl. Elec. and Det. Tech. 6 112
[39] Xu M F, Kuang S, Yu X, Zhang S J, Yan S, Remnev G E, Le X 2023 Nucl. Instruments Methods Phys. Res. Sect. B Beam Interact. with Mater. Atoms 537 38Google Scholar
[40] 陈伯显, 张智 2011 核辐射物理及探测学 (哈尔滨: 哈尔滨工程大学出版社) 第146页
Chen B X, Zhang Z 2011 Nuclear Radiation Physics and Detection (Harbin: Harbin Engineering University Press) p146
-
图 1 诊断方法示意图. 1-高压端柱; 2-阳极; 3-阳极托盘; 4-阴极; 5-阴极支撑盘; 6-电子; 7-离子束; 8-绝缘磁场线圈; 9-磁场线圈固定器; 10-有机玻璃观察窗; 11-CaF2窗口; 12-EJ-200塑料闪烁体; 13-9266 FLB光电倍增管
Fig. 1. Diagnostic method diagram. 1- High voltage input; 2-anode; 3- anode tray; 4-cathode; 5-cathode support plate; 6- electron; 7-ion beam; 8-insulated magnetic field coils; 9- magnetic field coils fixer; 10- organic glass observation window; 11-CaF2 window; 12-EJ-200 plastic scintillator; 13-9266 FLB photomultiplier tube.
图 3 红外相机在(a) IPIB辐照前、(b) IPIB辐照后从热沉靶背面捕获的红外图像, 以及(c)诊断系统捕获的脉冲X射线信号波形
Fig. 3. The infrared image captured by the infrared camera from the backside of the heat sink target before (a) IPIB irradiation, (b) after IPIB irradiation, and (c) the pulse X-ray signal waveform captured by the diagnostic system.
图 6 实验装置示意图. 1-高压端柱; 2-阳极; 3-阳极托盘; 4-阴极; 5-阴极支撑盘; 6-电子; 7-离子束; 8-绝缘磁场线圈; 9-磁场线圈固定器; 10-有机玻璃观察窗; 11-石墨收集体; 12-EJ-200塑料闪烁体; 13-9266 FLB光电倍增管
Fig. 6. Schematic diagram of experimental equipment. 1- High voltage input; 2-anode; 3- anode tray; 4-cathode; 5-cathode support plate; 6- electron; 7-ion beam; 8- insulated magnetic field coils; 9- magnetic field coils fixer; 10-organic glass observation window; 11-graphite collector; 12-EJ-200 plastic scintillator; 13-9266 FLB photomultiplier tube.
-
[1] Humphries S 1980 Nucl. Fusion 20 1549Google Scholar
[2] Van Devender J P 1986 Plasma Phys. Control. Fusion 28 841Google Scholar
[3] Long K A, Tahir N A 1982 Phys. Lett. A 91 451Google Scholar
[4] 杨海亮, 邱爱慈, 张嘉生, 何小平, 孙剑锋, 彭建昌, 汤俊萍, 任书庆, 欧阳晓平, 张国光, 黄建军, 杨莉, 王海洋, 李洪玉, 李静雅 2004 物理学报 53 406Google Scholar
Yang H L, Qiu A C, Zhang J S, He X P, Sun J F, Peng J C, Tang J P, Ren S Q, Ouyang X P, Zhang G G, Huang J J, Yang L, Wang H Y, Li H Y, Li J Y 2004 Acta Phys. Sin. 53 406Google Scholar
[5] Mach H, Rogers D W O 1983 IEEE Trans. Nucl. Sci. 30 1514Google Scholar
[6] Baumung K, Bluhm H J, Goel B, Hoppé P, Karow H U, Rusch D, Fortov V E, Kanel G I, Razorenov S V, Utkin A V, Vorobjev O Y 1996 Laser Part. Beams 14 181Google Scholar
[7] Zhong H W, Zhang J, Shen J, Liang G Y, Zhang S J, Huang W Y, Xu M F, Yu X, Yan S, Efimovich Remnev G, Le X Y 2019 Nucl. Instruments Methods Phys. Res. Sect. B Beam Interact. with Mater. Atoms 461 226Google Scholar
[8] Yu X, Zhang S J, Stepanov A V, Shamanin V I, Zhong H W, Liang G Y, Xu M F, Zhang N, Kuang S, Ren J, Shang X, Yan S, Remnev G E, Le X Y 2020 Surf. Coatings Technol. 384 125351Google Scholar
[9] 张世健, 喻晓, 钟昊玟, 梁国营, 许莫非, 张楠, 任建慧, 匡仕成, 颜莎, Gennady Efimovich Remnev, 乐小云 2020 物理学报 69 115202Google Scholar
Zhang S J, Yu X, Zhong H W, Liang G Y, Xu M F, Zhang N, Ren J H, Kuang S C, Yan S, Gennady E R, Le X Y 2020 Acta Phys. Sin. 69 115202Google Scholar
[10] Le X Y, Zhao W J, Yan S, Han B X, Xiang W 2002 Surf. Coatings Technol. 158 – 159 14
[11] 张锋刚, 朱小鹏, 王明阳, 雷明凯 2011 金属学报 47 958
Zhang F G, Zhu X P, Wang M Y, Lei M K 2011 Acta Metall. Sin. 47 958
[12] Zhang S J, Yu X, Zhang J, Shen J, Zhong H W, Liang G Y, Xu M, Zhang N, Ren J, Kuang S, Shang X, Adegboyega O, Yan S, Remnev G E, Le X Y 2021 Vacuum 187 110154Google Scholar
[13] Zhao W J, Remnev G E, Yan S, Opekounov M S, Le X Y, Matvienko V M, Han B X, Xue J M, Wang Y G 2000 Rev. Sci. Instrum. 71 1045Google Scholar
[14] Yan S, Le X Y, Zhao W J, Shang Y J, Wang Y, Xue J 2007 Surf. Coatings Technol. 201 4817Google Scholar
[15] Xu M F, Yu X, Zhang S J, Yan S, Tarbokov V, Remnev G, Le X Y 2023 Materials (Basel) 16 3028
[16] Yu X, Shen J, Zhong H W, Zhang J, Yan S, Zhang G L, Zhang X, Le X Y 2015 Vacuum 120 116Google Scholar
[17] Hashimoto Y, Yatsuzuka M 2000 Vacuum 59 313Google Scholar
[18] Prasad S V, Renk T J, Kotula P G, DebRoy T 2011 Mater. Lett. 65 4Google Scholar
[19] Suzuki T, Saikusa T, Suematu H, Jiang W, Yatsui K 2003 Surf. Coatings Technol. 169 – 170 491
[20] Zhu Q, Jiang W, Yatsui K 1999 J. Appl. Phys. 86 5279Google Scholar
[21] Shulov V A, Novikov A S, Paikin A G, Belov A B, Lvov A F, Remnev G E 2007 Surf. Coatings Technol. 201 8654Google Scholar
[22] Zhang J, Zhong H W, Shen J, Yu X, Yan S, Le X Y 2020 Surf. Coatings Technol. 388 125599Google Scholar
[23] Kovivchak V S, Panova T V, Mikhailov K A, Knyazev E V 2013 J. Surf. Investig. 7 531Google Scholar
[24] Zhang Q, Mei X X, Guan T, Zhang X N, Remnev G E, Pavlov S K, Wang Y N 2019 Fusion Eng. Des. 138 16Google Scholar
[25] Mei X X, Zhang X N, Liu X, Wang Y N 2017 Nucl. Instruments Methods Phys. Res. Sect. B Beam Interact. with Mater. Atoms 406 697Google Scholar
[26] Gerdin G, Stygar W, Venneri F 1981 J. Appl. Phys. 52 3269Google Scholar
[27] Christodoulides C E, Freeman J H 1976 Nucl. Instruments Methods 135 13Google Scholar
[28] Davis H A, Bartsch R R, Olson J C, Rej D J, Waganaar W J 1997 J. Appl. Phys. 82 3223Google Scholar
[29] Ryzhkov V A, Stepanov A V, Pyatkov I N, Remnev G E 2021 Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 1013 165671Google Scholar
[30] Ryzhkov V A, Pyatkov I N, Remnev G E 2021 Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 998 165190Google Scholar
[31] Pushkarev A I, Isakova Y I, Yu X, Khailov I P 2013 Rev. Sci. Instrum. 84
[32] Dong Z H, Liu C, Han X G, Lei M K 2007 Surf. Coatings Technol. 201 5054Google Scholar
[33] Masugata K, Chishiro E, Yatsui K 1998 Proceedings of the 12th International Conference on High-Power Particle Beams Haifa, Israel, June 12, 1998 pp222–225
[34] 杨海亮, 邱爱慈, 孙剑锋, 何小平, 汤俊萍, 王海洋, 李洪玉, 李静雅, 任书庆, 黄建军, 张嘉生, 彭建昌, 欧阳晓平, 张国光 2004 原子能科学技术 38 204
Yang H L, Qiu A C, Sun J F, He X P, Tang J P, Wang H Y, Li H Y, Li J Y, Ren S Q, Huang J J, Zhang J S, Peng J C, Ouyang X P, Zhang G G 2004 Atom. Ener. Sci. Tech. 38 204
[35] Yu X, Shen J, Isakova Y I, Zhong H W, Zhang J, Yan S, Zhang G L, Zhang X F, Le X Y 2015 Vacuum 122 12Google Scholar
[36] 屈苗, 喻晓, 张洁, 沈杰, 钟昊玟, 张艳燕, 颜莎, 张小富, 张高龙, 乐小云 2015 强激光与粒子束 27 216Google Scholar
Qu M, Yu X, Zhang J, Shen J, Zhong H W, Zhang Y Y, Yan S, Zhang X F, Zhang G L, Le X Y 2015 High Power Laser and Particle Beams 27 7Google Scholar
[37] 刘庆兆 1994 脉冲辐射场诊断技术 (北京: 科学出版社) 第98页
Liu Q Z 1994 Pulse Radiation Field Diagnosis Technology (Beijing: Science Press) p98
[38] 郑志鹏, 祝玉灿, 邵毓莺, 孙汉生 1986 核电子学与探测技术 6 112
Zheng Z P, Zhu Y C, Shao Y Y, Sun H S 1986 Nucl. Elec. and Det. Tech. 6 112
[39] Xu M F, Kuang S, Yu X, Zhang S J, Yan S, Remnev G E, Le X 2023 Nucl. Instruments Methods Phys. Res. Sect. B Beam Interact. with Mater. Atoms 537 38Google Scholar
[40] 陈伯显, 张智 2011 核辐射物理及探测学 (哈尔滨: 哈尔滨工程大学出版社) 第146页
Chen B X, Zhang Z 2011 Nuclear Radiation Physics and Detection (Harbin: Harbin Engineering University Press) p146
计量