串联超导量子干涉器件(superconducting quantum interference device, SQUID)阵列通过增加SQUID数量来达到提升信噪比的目的, 即SQUID电压信号随SQUID数目比例增加而总电压噪声正比于SQUID数目的平方根值. 本文介绍了利用自主工艺线进行串联SQUID阵列研究的相关研究进展, 实现了SQUID数量分别为200和800的阵列集成, 测试得到磁通噪声达到0.5
$ \text{μ}\varPhi _{\text{0}}/\sqrt{\text{Hz}} $ 和输入电流灵敏度35$ \text{μA/}\varPhi _{\text{0}} $ , 等效输入电流噪声达到18$ \text{pA/}\sqrt{\text{Hz}} $ . 另外, 还给出了阵列参数与集成SQUID数量的关系, 验证了设计可靠性和工艺一致性.Superconducting quantum interference device (SQUID) has been used as an extremely sensitive flux sensor up to now. Series SQUID array (SSA) is made up of several identical element-SQUIDs in series, in which each element-SQUID is coupled with the same set of input coils by mutual inductance to realize the amplified output of the input current. From the noise viewpoint, each element-SQUID in SSA is independent of each other, resulting in the total voltage noise across the array rising linearly with the square root of the number of element-SQUIDs. From the perspective of input signals, since the signals come from the same set of input coils, the voltage output of the array is enlarged with the proportion of element-SQUID number, N. Taken together, the signal-to-noise ratio of SSA is increased by$\sqrt{ {N}}$ times, or the flux noise of SSA is reduced by 1/$\sqrt{ {N}}$ times compared with that of an element-SQUID ideally. However, with the increase in the number of element-SQUIDs in series, the chip design of SSA becomes more complicated, which puts forward higher requirements for the consistency and stability of its fabrication process. Besides, there exists a certain flux coherence between element-SQUIDs in SSA, whose normal operation depends on the working state of each element-SQUID in the array. In this paper, the fabrication of series SQUID array is carried on the autonomous superconducting micro-nano process platform, with a yield rate reaching over 80% on a 4-inch standard silicon wafer. Two kinds of SSAs with 200 and 800 element-SQUIDs, respectively, are integrated in a meandering way on a chip in a millimeter area. Home-made directly-coupled readout circuit is used to obtain the characteristics of SSA. The experimental results reveal that the flux noise at best working point is as low as 0.5μ$\varPhi _{\text{0}}/\sqrt{\text{Hz}}$ and the current sensitivity is about 35 μA/Φ0, thus, the equivalent input current noise is achieved at a level of 18 pA/$ \sqrt{\text{Hz}} $ . Additionally, the dependence of relevant parameters in array on the number of element-SQUIDs is verified, which is consistent with theoretical expectation basically. These show that the reliability of device design and the consistency of fabrication process perform well, thus laying the technical foundation for developing the low-noise SQUID amplifier and the multiplexed readout of low-impedance detectors.-
Keywords:
- superconducting quantum interference device /
- flux noise /
- superconducting fabrication process
[1] Deaver B S, Fairbank W M 1961 Phys. Rev. Lett. 7 4
[2] Doll R, Näbauer M 1961 Phys. Rev. Lett. 7 51Google Scholar
[3] Josephson B D 1962 Phys. Lett. 1 251Google Scholar
[4] Josephson B D 1965 Adv. Phys. 14 419Google Scholar
[5] Forgacs R L, Warnick A 1967 Rev. Sci. Instrum. 38 214Google Scholar
[6] Drung D, Cantor R, Peters M, Scheer H J, Koch H 1990 Appl. Phys. Lett. 57 406Google Scholar
[7] Wang Y, Zhang G, Zhang S, Rong L, Xie X 2020 Physica C 569 1353590Google Scholar
[8] Seppä H, Ahonen A, Knuutila J, Simola J, Vikman V 1991 IEEE Trans. Magn. 27 2488Google Scholar
[9] Drung D 2010 Supercond. Sci. Technol. 23 065006Google Scholar
[10] Adelerhof D J, Kawai J, Uehara G, Kado H 1994 Appl. Phys. Lett. 65 2606Google Scholar
[11] Kang C S, Kim K, Lee S J, Hwang S M, Kim J M, Yu K K, Kwon H, Lee S K, Lee Y H 2011 J. Appl. Phys. 110 053906Google Scholar
[12] Xie X, Zhang Y, Wang H, Wang Y, Mück M, Dong H, Krause H J, Braginski A I, Offenhäusser A, Jiang M 2010 Supercond. Sci. Technol. 23 065016Google Scholar
[13] Kazami K, Kawai J, Uehara G, Kado H 1996 Jpn. J. Appl. Phys. 35 4322Google Scholar
[14] Falferi P, Mezzena R, Vinante A 2009 Supercond. Sci. Technol. 22 075020Google Scholar
[15] Kiviranta M, Gronberg L, Sipola H 2011 Supercond. Sci. Technol. 24 045003Google Scholar
[16] Welty R P, Martinis J M 1991 IEEE Trans. Magn. 27 2924Google Scholar
[17] Welty R P, Martinis J M 1993 IEEE Trans. Magn. 3 2605Google Scholar
[18] Morooka T, Myoren H, Takada S, Chinone K 2003 Jpn. J. Appl. Phys. 42 1375Google Scholar
[19] Morooka T, Tanaka K, Chinone K 2002 IEEE Trans. Appl. Supercond. 12 1866Google Scholar
[20] Lanting T, Dobbs M, Spieler H, Lee A T, Yamamoto Y 2009 Rev. Sci. Instrum. 80 094501Google Scholar
[21] Li K, Hubbell S P 1995 IEEE Trans. Appl. Supercond. 5 3255Google Scholar
[22] Stawiasz K G, Ketchen M B 1993 IEEE Trans. Appl. Supercond. 3 1808Google Scholar
[23] Semenov V K, Khapaev M M 2016 IEEE Trans. Appl. Supercond. 26 1300710Google Scholar
-
图 6 (a) SSA的正常态电阻Rn(方点)和最大电压调制幅度Vpp(星点)与SQUID数量之间的关系, 实线和虚线均为测试数据的线性拟合; (b) SSA的最大磁通-电压转换系数VΦ与SQUID数量之间的关系, 其中点为测试值, 线为线性拟合的结果
Fig. 6. (a) Normal resistance Rn (square dot) and maximum voltage swing Vpp (star dot) of SSA dependence on the SQUID-element number, in which the solid and dashed line are linear fittings, respectively (b) maximum flux-to-voltage coefficient VΦ dependence on the SQUID-element number, where the dots are experimental data and the line is the result of linear fitting.
表 1 SSA设计参数
Table 1. Design parameters of SSA.
参数 符号 数值 约瑟夫森结面积/(μm × μm) A 3 × 3 临界电流/μA Ic 9 结并联电阻/Ω Rs 1和4 垫圈尺寸/(μm × μm) — 8 × 28 单个SQUID电感/pH LS 100 输入线圈匝数/匝 — 2 输入线圈线宽/μm — 1 SQUID个数 N 200和800 输入电流灵敏度/(μA·$ \varPhi_0^{–1} $) 1/Mi 35 -
[1] Deaver B S, Fairbank W M 1961 Phys. Rev. Lett. 7 4
[2] Doll R, Näbauer M 1961 Phys. Rev. Lett. 7 51Google Scholar
[3] Josephson B D 1962 Phys. Lett. 1 251Google Scholar
[4] Josephson B D 1965 Adv. Phys. 14 419Google Scholar
[5] Forgacs R L, Warnick A 1967 Rev. Sci. Instrum. 38 214Google Scholar
[6] Drung D, Cantor R, Peters M, Scheer H J, Koch H 1990 Appl. Phys. Lett. 57 406Google Scholar
[7] Wang Y, Zhang G, Zhang S, Rong L, Xie X 2020 Physica C 569 1353590Google Scholar
[8] Seppä H, Ahonen A, Knuutila J, Simola J, Vikman V 1991 IEEE Trans. Magn. 27 2488Google Scholar
[9] Drung D 2010 Supercond. Sci. Technol. 23 065006Google Scholar
[10] Adelerhof D J, Kawai J, Uehara G, Kado H 1994 Appl. Phys. Lett. 65 2606Google Scholar
[11] Kang C S, Kim K, Lee S J, Hwang S M, Kim J M, Yu K K, Kwon H, Lee S K, Lee Y H 2011 J. Appl. Phys. 110 053906Google Scholar
[12] Xie X, Zhang Y, Wang H, Wang Y, Mück M, Dong H, Krause H J, Braginski A I, Offenhäusser A, Jiang M 2010 Supercond. Sci. Technol. 23 065016Google Scholar
[13] Kazami K, Kawai J, Uehara G, Kado H 1996 Jpn. J. Appl. Phys. 35 4322Google Scholar
[14] Falferi P, Mezzena R, Vinante A 2009 Supercond. Sci. Technol. 22 075020Google Scholar
[15] Kiviranta M, Gronberg L, Sipola H 2011 Supercond. Sci. Technol. 24 045003Google Scholar
[16] Welty R P, Martinis J M 1991 IEEE Trans. Magn. 27 2924Google Scholar
[17] Welty R P, Martinis J M 1993 IEEE Trans. Magn. 3 2605Google Scholar
[18] Morooka T, Myoren H, Takada S, Chinone K 2003 Jpn. J. Appl. Phys. 42 1375Google Scholar
[19] Morooka T, Tanaka K, Chinone K 2002 IEEE Trans. Appl. Supercond. 12 1866Google Scholar
[20] Lanting T, Dobbs M, Spieler H, Lee A T, Yamamoto Y 2009 Rev. Sci. Instrum. 80 094501Google Scholar
[21] Li K, Hubbell S P 1995 IEEE Trans. Appl. Supercond. 5 3255Google Scholar
[22] Stawiasz K G, Ketchen M B 1993 IEEE Trans. Appl. Supercond. 3 1808Google Scholar
[23] Semenov V K, Khapaev M M 2016 IEEE Trans. Appl. Supercond. 26 1300710Google Scholar
计量
- 文章访问数: 4613
- PDF下载量: 105
- 被引次数: 0